Choosing an Installation
Location
•
Select a location that will adequately support the
weight of the pump, as well as all plumbing and
electrical connections.
•
Refer to the mounting hole layout provided in
starting on page 51.
•
Always mount the pump upright.
•
If you have a mounting configuration that requires
installation in a manner different than depicted in
F
IG
. 6 or F
. 7, please contact your Graco distribu
-
tor for assistance.
Fluid Connections
1. Remove and discard plugs on check valves.
2. Connect a 1/4 npt(f) fluid line from the fluid source to
the inlet check valve (K). See F
IG
. 6 on page 17, or
3. Install a pressure relief valve (F) on the outlet side of
the pump.
NOTE:
A pressure relief valve is available from Graco
and can be connected back to the tank or directly to the
page 46.
4. Set the pressure relief valve at or below the maxi
-
mum working pressure of the pump.
5. Connect a 1/4 npt(f) fluid line from the outlet check
valve (L) to the injection point.
•
Connect a 10-32 UNF fluid outlet from the
prime/bleed valve (214) to the fluid source or waste
reservoir.
Motor Electrical Connections
In the event of an injection line blockage, to reduce the
risk of skin injection and damage to the pump, ensure
the pressure relief valve is set at or below the maxi
-
mum working pressure of the pump.
To reduce the risk of electrical shock;
•
All electrical wiring must be done by a qualified electri
-
cian and comply with all local codes and regulations.
•
Install the pump with a dedicated means to disconnect
the main power to the pump.
NOTICE
Branch circuit protection (user supplied) is required on all
models. To avoid equipment damage:
•
Never operate the pump without branch circuit pro
-
tection installed.
•
Branch circuit protection of the correct voltage and
amperage must be installed in line with the power
entry to the system.
•
Branch circuit protection should be UL248
approved.
•
See table below for branch circuit protection rating.
Configuration
Minimum Voltage
Branch Circuit
Protection
Rating
CI-12S-xx-x
12 VDC
15 A
CI-12L-xx-x
12 VDC
20 A
CI-12B-xx-x
12 VDC
20 A
CI-12H-xx-x
12 VDC
25 A
CI-24H-xx-x
24 VDC
15 A
CI-24B-xx-x
24 VDC
15 A
CI-1AJ-xx-x
115 VAC
3 A
CI-1AL-xx-x
115 VAC
3 A
CI-1AD-xx-x
115 VAC
4 A
CI-2AL-xx-x
230 VAC
2 A
CI-3AH-xx-x
115 VAC (Single Phase)
5 A
CI-3AH-xx-x
230 VAC (Single Phase)
3 A
CI-4AL-xx-x
230 VAC (3 Phase)
1 A
CI-4AL-xx-x
460 VAC (3 Phase)
1 A
CI-4AH-xx-x
230 VAC (3 Phase)
1.25 A
CI-4AH-xx-x
460 VAC (3 Phase)
1 A
CI-24X-xx-x
24 VDC
15 A
CI-2AX-xx-x
230 VAC
2 A
CI-5AX-xx-x
230 VAC (3 Phase)
2 A
CI-5AX-xx-x
400 VAC (3 Phase)
1 A