Daily
Daily
Daily System
System
System Care
Care
Care
1.
Follow the
Pressure Relief Procedure, page 39
.
2.
Clean the fluid and air filters.
3.
Check for fluid leaks. Tighten all fittings.
4.
Clean workpiece hangers. Use non-sparking
tools.
5.
Check the movement of the trigger and valves.
Lubricate if necessary.
6.
Check Gun Electrical Grounding, page 38
.
7.
Hang the gun from its hook, with the nozzle
pointing down. Be sure to keep the gun from
grounding out.
8.
Clean the cabinet:
• Inspect the cabinet and clean up any spilled
paint. Conductive paint residue allowed to
contact grounded parts may short out the
electrostatics.
• Keep the inside of the cabinet clean, for proper
operation.
• Inspect the door T-handle locking screw
regularly, to ensure the threads are well
greased. Apply silicone-free grease to the
threads when necessary.
• Visually inspect the ground strip (240)
for damage. Replace if needed.
Measure the resistance weekly. See
Test Ground Strip Resistance, page 50
.
46
3A2496H