Tubing
Tubing
Tubing and
and
and Wiring
Wiring
Wiring Chart
Chart
Chart
Use the diagrams to find the connection points for
the tubing and wiring listed below.
Code
Code
Code
Ref.
Ref.
Ref. No.
No.
No.
Length
Length
Length
in.
in.
in. (mm)
(mm)
(mm)
Description
Description
Description
A1
248
20 (508)
1/4 OD tube, regulator
(216) to pump
A2
248
9 (229)
1/4 OD tube, regulator
(216) to manifold
B2
249
17 (432)
5/32 OD tube, manifold air
to door interlock switch
B3
249
20 (508)
5/32 OD tube, valve tee to
cylinder
B4
249
5 (127)
5/32 OD tube, regulator
(216) to gauge (217)
B5
249
22 (559)
5/32 OD tube, valve tee to
door interlock switch
C1
272
9 (229)
red 14 gauge wire from top
of bleed resistor to meter
C2
251
8 (204)
green/yellow 14 gauge wire
from internal box ground
lug to cylinder cap
C3
273
34 (864)
green/yellow 10 gauge wire
from external ground lug to
cart
Code
Code
Code
Ref.
Ref.
Ref. No.
No.
No.
Length
Length
Length
in.
in.
in. (mm)
(mm)
(mm)
Description
Description
Description
C4
239
n/a
green/yellow 25 ft (7.6 m)
ground wire with clamp,
from external ground lug to
true earth ground
C5
243
n/a
green/yellow 10 gauge wire
from external ground lug to
ground probe
C6
226
n/a
red wire from bleed resistor
to pump
C7
272
16 (407)
red 14 gauge wire from
pump to pail cover with
clamp
C8
272
12 (305)
red 14 gauge wire from
pump (209) to ground on
cylinder bracket
C9
251
n/a
green/yellow 10 gauge wire
from meter (+) to internal
box ground lug
E1
286
4 (102)
3/8 OD tube, bulkhead to
manifold
3A2496H