5.
Connect the waterborne hose. Follow the steps
in
Connect the Waterborne Fluid Hose, page 17
6.
Connect the red Graco grounded air hose to the
gun air inlet. The gun air inlet fitting has left-hand
threads. See
7.
Follow all steps in
8.
Follow all steps in
Check Gun Electrical Grounding, page 38
.
Reading must be less than 100 ohms.
9.
Connect the exhaust tube and secure with the
clamp provided.
10. Flush if needed. See
.
11. Position the air cap as needed.
12. Fully open the fan air adjustment valve (F)
counterclockwise.
13. Fully open the fluid adjustment valve (H)
counterclockwise.
14. Fully open the atomizing air restrictor valve (G)
clockwise.
15. Turn ON (I) the ES On-Off switch (J).
When the ES On-Off switch is turned ON (I),
the fluid supply is charged with high voltage
until the voltage is discharged. Contact with
the charged components of the spray gun will
cause an electric shock. Do not touch the gun
nozzle or electrode or come within 4 in. (102
mm) of the front of the gun during operation.
3A2496H
27