Merkur
Merkur
Merkur 3400,
3400,
3400, 36:1
36:1
36:1 Pump
Pump
Pump Modules
Modules
Modules
1
Torque to 50–60 ft-lb (68–81 N•m).
2
Torque to 145–155 ft-lb (196–210 N•m).
3
Coat mounting surface of sensor mounting
block(322) with non-silicone heat sink compound.
Do not coat sensor.
4
Prior to tightening band clamp (321), RTD sensor
(20)must be fully contained within the sensor
mount (322).
5
After fastening band clamp (321), secure excess
with fiberglass tape.
6
Coat inside of heater (309) only to within 0.75 in.
(19 mm) of vertical ends) with non-silicone heat
sink compound before mounting.
7
Cap screws (311) must be loose while tie rods
(307) are being torqued.
8
Torque to 150 ft-lb (203 N•m).
9
Install swivel fitting (302) prior to screw (303)
and reed switch assembly (304).
10
Apply anaerobic sealant to threads.
76