Code
Code
Code
Description
Description
Description
Type
Type
Type
Cause
Cause
Cause
Solution
Solution
Solution
V6M#
Wiring Error
Line MZLP _
Alarm
Incoming
power is wired
incorrectly
Correct the Wiring.
Verify transformer has the correct tap selected.
Verify CB-1 or FU-4, FU-5, and FU-6 are not
tripped/blown.
Verify RCD-1 is not tripped.
Measure incoming power with system unplugged. If
line voltage is less than 100 VAC, contact qualified
electrician to correct the low voltage.
V8M#
No Line Voltage
MZLP _
Alarm
Incoming line
voltage is less
than 100 VAC.
Verify the MZLP is plugged in at J2 and the AWB is
plugged in at J5 and J6.
Check incoming voltage is correct for configuration.
V4M#
AWB High Line
Voltage
Alarm
Incoming
voltage is too
high
Verify the transformer has the correct tap (400, 480,
600) selected.
Verify harness is plugged into J13 of the daughter
board. Verify it is secured to the solenoid.
WJ1
Pump _
Solenoid is
disconnected
Alarm
Pump is not
turning on
when it should Replace Solenoid.
WJ2
Pump _
Solenoid High
Current
Alarm
Solenoid is
drawing too
much current
Inspect for short in harness. Inspect for a shorted
solenoid cable/short to the ground. Replace solenoid.
WSUX
Configuration
Error USB
Advisory
USB
configuration
is not loaded
Install software.
42
334130D
Содержание Therm-O-Flow 200
Страница 48: ...Repair Figure 28 48 334130D...
Страница 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Страница 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Страница 60: ...Electrical Schematics 400 600VV 400 600VV 400 600VV 3 3 3 Phase 60 Phase 60 Phase 60 Hz Hz Hz 60 334130D...
Страница 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Страница 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Страница 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Страница 68: ...Parts 68 334130D...
Страница 94: ...Accessories and Kits 94 334130D...