5
308718
Preparation
Compressor Break-in
The first time you use the system, run the compressor
under no load for 15 minutes to break it in, improve its
performance, and lengthen its life.
1.
Connect the air hose to the air outlet (A) and to the
gun air inlet. Open gun air valve (423), and turn air
restrictor valve (424) all the way to the + position.
See Fig. 2.
Fig. 2
7070B
A
7132A
423
(shown
open)
424
2.
Turn the ON/OFF switch (D) ON. Run the system
for 15 minutes. Turn the switch OFF. See Fig. 3.
Fig. 3
D
7078B
WARNING
PRESSURIZED EQUIPMENT HAZARD
The system pressure must be manually relieved to
prevent the system from starting or spraying
accidentally. To reduce the risk of an injury from
accidental spray from the gun, splashing fluid, or
moving parts, follow the Pressure Relief
Procedure whenever you
Are instructed to relieve the pressure
Stop spraying
Check or service any of the system equipment
Install or clean the spray nozzle
Pressure Relief Procedure
1.
Shut off the system.
2.
Trigger the gun, and spray the material back into
the hopper.
3.
Open the gun air valve (handle parallel with valve
body).
4.
Unplug the electrical power cord.
5.
Place a rag over the pump outlet fitting (B in
Fig. 1), and slowly open the cam locks to relieve
residual pressure.