Preparation
Grounding and Electrical Requirements
WARNING
Improper installation or alteration of the grounding
plug will result in a risk of electric shock, fire or
explosion that could cause serious injury or death.
Extension Cords
Use only an extension cord with an undamaged,
3-prong plug.
For up to 25 ft (7.6 m) cord, use 3-wire, 12 AWG
(1.5 mm
2
) minimum.
For 25 to 50 ft (7.6 to 15.2 m) cords, use 3-wire,
10 AWG (2.5 mm
2
) minimum.
120V AC Systems
This equipment requires a 120V AC, 60 Hz, 15A
circuit with a grounding receptacle. See Fig. 4.
Fig. 4
grounding prong
grounded
outlets
Do not alter the ground prong or use an
ungrounded adapter.
A maximum length of 25 ft, 12 AWG or 50 ft,
10 AWG extension cord may be used.
240V AC Systems
This equipment requires a 240V AC, 50 Hz, 16A
circuit with a grounding receptacle. See Fig. 5.
Fig. 5
grounded
outlet
grounding prong
Do not alter the ground prong or use an
ungrounded adapter.
A maximum length of 8 m, 1.5 mm
2
or 15 m,
2.5 mm
2
extension cord may be used.
System Setup
1.
Connect the hoses and gun as shown See Fig. 6.
Fig. 6
7072B
2.
Be sure the air filter (K) and the material screen (L)
are in place. See Fig. 7.
3.
Plug the power cord into a properly grounded
outlet.
Fig. 7
K
1
Located inside hopper
L
07073B
1