Operation
Operation
Operation
Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from moving parts, or from pressurized fluid,
such as splashing in the eyes or on skin, follow
the Pressure Relief Procedure when you stop
pumping and before you clean, check, or service
the equipment.
1.
Close the air motor slider valve (BH) and the
main air slider valve (BA).
NOTE
NOTE
NOTE: Both are relieving air valves.
2.
Set the ram director valve (BD) to DOWN. The
ram will slowly drop.
3.
Jog the ram director valve (BD) up and down to
bleed air from ram cylinder.
4.
Open dispense valve or trigger gun to relieve
pump output pressure.
Flush
Flush
Flush the
the
the Pump
Pump
Pump Before
Before
Before First
First
First Use
Use
Use
The pump was tested in water. If water could
contaminate the fluid you are pumping, flush the
pump thoroughly with a compatible solvent. See
pump manual for detailed cleaning instructions.
Start
Start
Start and
and
and Adjust
Adjust
Adjust Ram
Ram
Ram
1.
Raise the ram:
a.
Open the main air slider valve (BA) and set
the ram air regulator (BB) to 30 psi (0.21
MPa, 2.1 bar).
b.
Move the ram director valve (BD) handle to
UP. Allow the ram to rise to full height.
c.
When the ram is at its full height, move the
ram director valve (BD) handle to the neutral
(center) position.
2.
Place a full pail on the base and center it under
the Platen (D).
3.
Adjust the pail to be sure it is aligned with the
platen, and open the platen bleed port (J).
NOTE:
NOTE:
NOTE: If the platen is not aligned properly for
entering the pail, when the platen reaches the
top of the pail, move the ram director valve (BD)
handle to the neutral position and move the pail.
Then continue lowering the platen into the pail.
4.
With hands away from the pail and the platen,
move the ram director valve (BD) handle to
DOWN, and lower the ram until the platen lowers
into the pail and fluid begins to come out of the
platen bleed port (J).
5.
Move the ram director valve (BD) handle to the
neutral position.
6.
Close the platen bleed port (J).
Start
Start
Start and
and
and Adjust
Adjust
Adjust the
the
the Pump
Pump
Pump
1.
Connect pump outlet fittings and hose (not
supplied).
NOTE:
NOTE:
NOTE: Be sure all components are adequately
sized and pressure rated to meet the system’s
requirements.
2.
Be sure the pump air valve (BE) is closed. Set
the pump air regulator (BB) to about 30 psi
(0.21 MPa, 2.1 bar). Set the ram director valve
(BD) handle to DOWN. See manual 3A5800 for
SaniForce air controls instructions and parts.
3.
Open the pump air motor slider valve (BH).
4.
Keep the ram director valve (BD) handle DOWN
while pump is operating.
NOTE:
NOTE:
NOTE: Increase air pressure to the ram if the
pump does not prime properly with heavier fluids.
Decrease air pressure if fluid is forced out around
the top seal or platen.
8
3A5400B