Integrated
Integrated
Integrated Air
Air
Air Control
Control
Control
The integrated air control includes:
• Source
Source
Source air
air
air supply
supply
supply (A1):
(A1):
(A1): facility air supply to power
SPU.
• Air
Air
Air motor
motor
motor drive
drive
drive air
air
air (A2):
(A2):
(A2): air supply to drive pump
air motor.
• Main
Main
Main air
air
air slider
slider
slider valve
valve
valve (BA):
(BA):
(BA): turns air on and off to the
system. When closed, the valve relieves pressure
downstream.
• Ram
Ram
Ram air
air
air regulator
regulator
regulator (BB):
(BB):
(BB): controls ram up and down
pressure and blowoff pressure.
• Ram
Ram
Ram air
air
air pressure
pressure
pressure gauge
gauge
gauge (BC):
(BC):
(BC): displays the air
pressure used to raise and lower the ram.
• Ram
Ram
Ram director
director
director valve
valve
valve (BD):
(BD):
(BD): controls ram direction.
• Air
Air
Air motor
motor
motor regulator
regulator
regulator (BE):
(BE):
(BE): controls air pressure to
motor.
• Air
Air
Air motor
motor
motor pressure
pressure
pressure gauge
gauge
gauge (BF):
(BF):
(BF): displays the air
pressure used to drive the air motor.
• Blowoff
Blowoff
Blowoff button
button
button (BG):
(BG):
(BG): turns air on and off to push
the platen out of an empty pail.
• Air
Air
Air motor
motor
motor slider
slider
slider valve
valve
valve (BH):
(BH):
(BH): turns air on and off to
the air motor. When closed, the valve relieves air
trapped between it and the air motor. Push the
valve in to shutoff.
Air
Air
Air Line
Line
Line Accessories
Accessories
Accessories
See Fig. 1.
• Air
Air
Air line
line
line drain
drain
drain valve
valve
valve (U)
(U)
(U)
• Air
Air
Air line
line
line filter
filter
filter (V):
(V):
(V): removes harmful dirt and moisture
from compressed air supply.
• Second
Second
Second bleed-type
bleed-type
bleed-type air
air
air valve
valve
valve (W):
(W):
(W): isolates air line
accessories and supply system for servicing.
Locate upstream from all other air line accessories.
• Air
Air
Air relief
relief
relief valve
valve
valve (100
(100
(100 psi):
psi):
psi): (two attached to ram
integrated air controls for pump and ram air, not
visible): automatically relieves excessive pressure.
Grounding
Grounding
Grounding
The equipment must be grounded to reduce the
risk of static sparking. Static sparking can cause
fumes to ignite or explode. Grounding provides an
escape wire for the electric current.
Before operating the pump, ground the system as
explained below.
• Pump:
Pump:
Pump: Connect the grounding wire attached to the
bracket to a true earth ground.
• Air
Air
Air and
and
and fluid
fluid
fluid hoses:
hoses:
hoses: Use only grounded hoses with
a maximum of 500 ft (150 m) combined hose length
to ensure grounding continuity. Check electrical
resistance of hoses. If total resistance to ground
exceeds 29 megohms, replace hose immediately.
• Spray
Spray
Spray gun/dispense
gun/dispense
gun/dispense valve:
valve:
valve: ground through
connection to a properly grounded fluid hose and
pump.
• Fluid
Fluid
Fluid supply
supply
supply container:
container:
container: Follow local code.
• Solvent
Solvent
Solvent pails
pails
pails used
used
used when
when
when flushing:
flushing:
flushing: Follow local
code. Use only conductive metal pails, placed
on a grounded surface. Do not place the pail
on a nonconductive surface, such as paper or
cardboard, which interrupts grounding continuity.
Check your system electrical continuity between the
ground wire end and the pump fluid outlet after the
initial installation, and then set up a regular schedule
for checking continuity to be sure proper grounding
is maintained. The resistance should not exceed 10
ohms. Ground cable 244524 is available separately.
Fluid
Fluid
Fluid Outlet
Outlet
Outlet Line
Line
Line
Connect a grounded, flexible fluid hose (S) to the
fluid outlet port. The port is a 1.5 in (38 mm) sanitary
flange.
3A5400B
7
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910