Repair
38
313221A
To Remove Entire Pump Assembly
4. Disconnect suction tube. See page 37. Also
disconnect steel outlet tube (16) from
heater inlet.
5. Remove pump rod cover (222). Push clip
up in back and push pin (217) out. Loosen
locknut (218) by hitting firmly right-to-left
with a non-sparking hammer. Unscrew
pump. See manual 311076 for pump repair
and parts.
6. Install pump in reverse order of disassem-
bly, following all notes in F
IG
. 9. Clean
strainer (51). Reconnect suction tube and
outlet (D) lines.
7. Tighten fluid outlet fitting (D), then tighten
locknut (218) by hitting firmly with a
non-sparking hammer.
8. Set function knob to Slow Recirc
.
Purge air and prime. See page 17.
F
IG
. 9. Displacement Pump
D
16
217
1
Flat side faces up. Tighten by hitting
firmly with non-sparking hammer.
1
Lubricate threads with ISO oil or grease.
2
2
2
218
222
E
207
51