Troubleshooting
313221A
31
B side rich; lack of A side.
A side gauge is low.
A side material supply problem.
Check A side inlet strainer and
pump intake valve.
B side gauge is low.
A side restriction downstream of
gauge. Check gun check valve
screen, mix module, or mix mani-
fold restrictor.
No temperature display.
Loose display cables on control
board.
Check cable connections to each
display, page 42.
Failed control board (displays get
power from control board).
Remove access panel. Check if
board LED is lighted. If not,
replace board, page 42.
Inadequate power to control
board.
Check that power supply meets
requirements.
Loose power cable.
Check cable connections, page
42.
Motor Power switch circuit
breaker tripped.
Display is powered from Motor
Power circuit breaker. Cycle Motor
Power off
, then on
to reset breaker.
Wrong temperature displayed.
°F/°C switch in wrong position.
Set switch, see page 39.
Temperature displays do not
match at ambient temperature.
Displays need calibration.
Turn calibration screw on back of
displays to correct reading, see
page 39.
PROBLEM
CAUSE
SOLUTION