Setup
313221A
13
Setup
Connect Reactor E-10 to the correct power
source for your model. See T
ABLE
2. Models
with two power cords must be connected to
two separate, dedicated circuits. See F
IG
. 5.
The equipment must be grounded. Grounding
reduces the risk of static and electric shock by
providing an escape wire for the electrical cur-
rent due to static build up or in the event of a
short circuit.
1.
Locate Reactor E-10
a.
Locate Reactor E-10 on a level
surface.
b.
Do not expose Reactor E-10 to
rain.
2.
Electrical requirements
Improper wiring may cause electric shock or
other serious injury if work is not performed
properly. Have a qualified electrician perform
any electrical work. Be sure your installation
complies with all National, State and Local
safety and fire codes.
3.
Ground system
a.
Reactor E-10: grounded through
power cord.
b.
Generator (if used): follow your
local code. Start and stop gener-
ator with power cord(s) discon-
nected.
c.
Spray gun: grounded through the
supplied fluid hoses, connected
to a properly grounded Reactor
E-10. Do not operate without at
least one grounded fluid hose.
d.
Object being sprayed: follow your
local code.
e.
Solvent pails used when flushing:
follow your local code. Use only
metal pails, which are conduc-
tive, placed on a grounded sur-
face. Do not place pail on a
nonconductive surface, such as
paper, plastic, or cardboard,
which interrupts grounding conti-
nuity.
f.
To maintain grounding continuity
when flushing or relieving pres-
sure, hold a metal part of spray
gun firmly to the side of a
grounded metal pail, then trigger
gun.