Cellular Screen

3A5540D

13

Cellular Screen

Use this screen to connect the Reactor Connect to the 
Reactor, determine the cellular signal strength, or reset 
the Reactor Key.

View Cellular Screen

1. On the Reactor ADM, press 

 to enter the 

setup mode.

2. Press 

 to go to the Cellular screen.

Reset Reactor Key

Resetting your Reactor Key prevents other users from 
remotely changing or viewing Reactor settings without 
first reconnecting to the Reactor.

1. On the Reactor ADM Cellular screen, press 

 

to reset the Reactor key.

2. Press 

 to confirm resetting the Reactor key.

3. Reconnect your app to the Reactor. See 

Connect 

App to Reactor

, page 11.

NOTE: 

After resetting your Reactor key, all operators 

using the Graco Reactor Connect must reconnect to the 
Reactor.

NOTE:

 For security of wireless control, change the 

Reactor key on a regular basis and whenever there is a 
concern about unauthorized access.

F

IG

. 5: ADM Cellular Screen

Содержание Reactor 25D612

Страница 1: ...only Models 25D612 25E656 Important Safety Instructions Read all warnings and instructions in this manual and in the Reactor 2 manual Save all instructions IMPORTANT By operating your Reactor 2 system...

Страница 2: ...15 Accessories 15 Technical Specifications 17 Graco Standard Warranty 18 Graco Information 18 Models Related Manuals Kit Included Cellular Module Description 25D612 25M720 3G cellular module operatio...

Страница 3: ...Agency Approvals NOTE Cellular module kit 25M833 contains Part 25M720 Cellular module kit 25E658 contains Part 25N372 Description Approvals MODULE cellular worldwide 25M720 MODULE cellular United Sta...

Страница 4: ...are compatible with equipment wetted parts See Technical Specifications in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request Saf...

Страница 5: ...Warnings 3A5540D 5...

Страница 6: ...Typical Installation 6 3A5540D Typical Installation FIG 1 Typical Reactor Connect Cell Module Installation Reactor 2 Electric Shown WL D A C D B E F CA AA...

Страница 7: ...Reactor 2 Electric Shown WL D ADM B A D F E C AA Ref Description A Cellular Module AA Cellular Module Nuts ADM Advanced Display Module B Antenna C Bracket CA Bracket Screws D Cellular Module CAN Cable...

Страница 8: ...ed by an on site operator In any lock out tag out procedure take into consideration the potential for changes to the Reactor 2 settings due to remote operation To avoid injury due to unexpected machin...

Страница 9: ...the unattached end of the cellular CAN cable 13 Slide the CAN cable to the top inside corner of the electrical cabinet door NOTE To minimize cable strain during door operation locate the CAN cable as...

Страница 10: ...n you may see the following screens 8 Remove the software update token 9 Replace the token access panel 10 Remount the ADM using the four ADM mounting screws Tighten the screws fully 11 Close and lock...

Страница 11: ...re connecting the Reactor to an app for the first time Reset Reactor Key See page 13 3 To connect the app to the Reactor scan the code a Select the Scan code button on the app See FIG 4 b Using the ap...

Страница 12: ...Reactor Status H Reactor Name J Menu K Reactor Power Switch L Heat Zone Settings M Heat Zone On Off N Heat Zone Actual Temperature P Heat Zone Temperature Setpoint R Proportioner Start Stop Switch S...

Страница 13: ...remotely changing or viewing Reactor settings without first reconnecting to the Reactor 1 On the Reactor ADM Cellular screen press to reset the Reactor key 2 Press to confirm resetting the Reactor key...

Страница 14: ...le status LEDs are illuminated No power to cellular module Turn Reactor proportioner on Ensure cellular module is properly installed See Installation page 9 No network connection Still establishing ce...

Страница 15: ...cellular module worldwide 1 25E658 KIT cellular module United States and Canada only 1 3 25M828 ANTENNA paddle 1 4 127158 NUT 8 32 2 5 121002 CABLE can 1 6 124654 TEE CAN 1 7 25M832 TAG agreement not...

Страница 16: ...Parts 16 3A5540D...

Страница 17: ...U201 Band Support Band 19 800 MHz Band 5 850 MHz Band 8 900 MHz Band 2 1900 MHz Band 1 2100 MHz WCDMA HSDPA HSUPA Power Class Power Class 3 24 dBm for WCDMA HSDPA HSUPA mode Cellular Module 25N372 FC...

Страница 18: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: