Alarm Troubleshooting
312776K
93
E-25: AUTO DUMP COMPLETE ALARM
Cause
Solution
A potlife alarm is active for more than 2 minutes, the gun
flush box is enabled and gun is in the gun flush box, and
an auto dump flush sequence is complete.
Be sure to spray all mixed material before potlife expires.
E-26: COLOR/CATALYST PURGE ALARM
Cause
Solution
System detects no meter pulses, or a disruption in meter
pulses lasting longer than 1 second throughout the
Color/Catalyst purge time duration.
Check that meter cable is connected.
Clean or repair meter.
E-27: COLOR/CATALYST FILL ALARM
Cause
Solution
System detects no meter pulses, or system must detect
at least 10cc of material from each side throughout the
Color/Catalyst fill time duration.
Check that meter cable is connected.
Clean or repair meter.
Gun, dump valve, or correct color/catalyst valve not
open.
Open the valve.
Exhausted fluid supply.
Check fluid level and refill if necessary.
Switch settings (S3-S6) on color change board do not
match hardware configuration.
Verify that color change board switches are set correctly.
See installation manual.
Fuse F1, F2, or both are blown.
Verify condition of fuses and replace if necessary. See
Repair-Parts manual.
E-28: MIX FILL PUSH COMPLETE
Cause
Solution
Mix fill push has been completed.
Potlife expired material has been purged.
Table 11. Alarm Troubleshooting