Setup Mode
312776K
33
DD Setup Mode
Selecting “DD” in the Dose Size field makes the
Dynamic Dosing setup mode field appear. Select On to
enable DD setup mode, or Off to disable. See page 51
for further information.
Configure Screen 5
Special Outputs
Use of Special Outputs on Manual systems requires
installation of a Discrete I/O Integration Board. Order
Graco Part No. 15V825 Discrete I/O Integration Board
Kit. See manual 406800.
NOTE
: At system power up, the Special Outputs may
activate for up to 1/4 second.
Select special outputs (0-4, or 3 + GFB on #4). A selec-
tion of “0” will disable use of the Special Outputs. If the
“3 + GFB on #4” selection is chosen, the other 3 special
outputs (1-3) can be used for user-defined functions and
the special output #4 settings will duplicate those set-
tings established for the Gun Flush Box.
Each output has two different start times and durations
defined on the Recipe Setup screen (Flush and Fill Input
is set to “Recipe” in
, page 34), or on
the Advanced Setup screen (Flush and Fill Input is set
to “Global” in
Solvent Monitor
Select solvent monitor (Off, Flow Switch, or Meter).
A selection of “Meter” will cause the system to track the
amount of solvent used. See
, page 25
for more information about solvent totals.
Web Browser IP
The default web browser IP address prefix is
192.168.178.__ Assign a unique number for each
EasyKey in your system (1-99) and enter it here.
Control Network ID
Used for the Graco Gateway network system. See
Graco Gateway manual 312785 for further information.
F
IG
. 26. Configure Screen 4, dynamic dosing
selected
F
IG
. 27. Configure Screen 4, dynamic dosing setup
mode enabled
F
IG
. 28. Configure Screen 5