Graco Motor Control Operation (BLDC Models)
G231
SET MAINTENANCE
INTERVAL 2
Set the desired maintenance interval in millions of cycles.
• Range is 0.1 — 99.9 million cycles.
• Enter 0 to disable the maintenance counter.
• Default is 0.
G232
SET MAINTENANCE
INTERVAL 3
Set the desired maintenance interval in millions of cycles.
• Range is 0.1 — 99.9 million cycles.
• Enter 0 to disable the maintenance counter.
• Default is 0.
G240
SET MINIMUM FLOW
SETPOINT
Set the lowest selectable flow setpoint.
• Units are user selectable. See Set Flow Units (menu G201).
• Menu is visible only if Control Mode (menu G200) is set to flow (0) or if External
Control (menu G209) is set to full control (3).
• Range is 0–280 cycles per minute.
• Default is 0.
Example: If you want the system to dispense at least 5 lpm, set the control mode to
flow control (menu G200), and the flow units to liters (menu G201). Set this menu
to 5. Users will not be able to enter a minimum setpoint lower than 5 lpm.
G241
SET MAXIMUM FLOW
SETPOINT
Set the highest selectable flow setpoint.
• Units are user selectable. See Set Flow Units (menu G201).
• Menu is visible only if Control Mode (menu G200) is set to flow (0) or if External
Control (menu G209) is set to full control (3).
• Range is 0–280 cycles per minute.
• Default is 280.
Example: If you want the system to dispense no more than 10 lpm, set the control
mode to flow control (menu G200) and set the flow units to liters (menu G201).
Set this menu to 10. Users will not be able to enter a maximum setpoint higher
than 10 lpm.
G245
SET MINIMUM VOLUME
SETPOINT
Set the lowest selectable volume setpoint.
• Units are user selectable. See Set Flow Units (menu G201).
• Menu is visible only if Control Mode (menu G200) is set to batch (1).
• Range is 0–9999 cycles.
• Default is 0.
Example: If you want the system to dispense at least 15 gallons in each batch, set
the control mode to batch control (menu G200) and set the flow units to gallons
(menu G201). Set this menu to 15. Users will not be able to enter a minimum
setpoint lower than 15 gallons.