Graco Motor Control Operation (BLDC Models)
G246
SET MAXIMUM VOLUME
SETPOINT
Set the highest selectable volume setpoint.
• Units are user selectable. See Set Flow Units (menu G201).
• Menu is visible only if Control Mode (menu G200) is set to batch (1).
• Range is 0–9999 cycles.
• Default is 9999.
Example: If you want the system to dispense no more than 50 gallons in each
batch, set the control mode to batch control (menu G200) and set the flow units
to gallons (menu G201). Set this menu to 50. Users will not be able to enter a
maximum setpoint higher than 50 gallons.
G247
BATCH MODE TARGET
FLOW
Set the flow rate to use while in batch control mode.
• Units are user selectable. See Set Flow Units (menu G201).
• Menu is visible only if Control Mode (menu G200) is set to batch (1).
• This menu is not editable if external controls (menu G209) are configured for full
control (3). The system displays the setpoint as set by the analog input.
• Range is 1–280 cycles per minute.
• Default is 10 cpm.
G248
BATCH START INTERVAL
Menu is only visible if G200 is set to 1. Set the number of seconds to elapse
from the start of a batch until the next batch will be started automatically. When
the interval timer counts down to zero, it will once again return to the entered
value, begin counting down, and the batch is started. If the current batch has not
completed by the time the timer reaches zero, the next batch will not begin until
the next time the timer counts down to zero. The pump must be stopped to edit
this field.
• Range is 0 — 99999
• Default is 0 (disable)
G300
VIEW FLOW RATE
Display the pump flow rate
• User cannot edit.
• Units are user selectable. See Set Flow Units (menu G201).
G302
VIEW BUS VOLTAGE
Displays the BUS voltage in V.
• User cannot edit.
G303
VIEW MOTOR VOLTAGE
Displays the RMS motor voltage in V.
• User cannot edit.
G304
VIEW MOTOR CURRENT
Displays the RMS motor current in A.
• User cannot edit.
G305
VIEW MOTOR POWER
Displays the motor power in W.
• User cannot edit.
G306
VIEW CONTROLLER
TEMPERATURE
Displays the IGBT temperature in °C.
• User cannot edit.
38
334188P
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910