Setup
313888E
15
Spray Without Air - Clear Clog
1.
Relieve Pressure
, page 10.
2.
Rotate SwitchTip to Clear position. Aim applicator at
floor and turn pump ON. When clog clears, turn
pump OFF.
3.
Rotate SwitchTip to Spray position. Turn pump ON.
Spray test pattern.
Air Assisted Spray
(Base Coat Applicator)
1.
Prepare material, page 13. Place material hose in
supply pail.
2.
Turn on/off switch OFF.
3.
Remove cap and install air valve assembly.
4.
Turn air valve OFF. Connect applicator to material
hose and air hose. Air supply minimum require-
ments vary with material thickness and desired
thickness.
5.
Turn on/off switch ON.
6.
Hold applicator over material pail and turn pump ON
using applicator switch on hose.
7.
Turn pump control clockwise until desired material
delivery rate is achieved.
ti11714a
ti11715a
ti10796b
ti13647a
NOTICE
DO NOT USE MATERIALS THAT CURE RAPIDLY!
Materials with a fast curing time could plug the pump
hose, gun, or applicator.
ti21037a
ti10795b
ti13641a
ti8794a
ti5251a