E5F_
E5F_
E5F_
Advanced
None
Advisory Dual lower system calibration error. System running too
rapidly to perform calibration.
E5N_
E5N_
E5N_
Basic and
Advanced
2–7
Deviation Calibrate stroke failed.
E5S_
E5S_
E5S_
Advanced
None
Advisory Dual lower system calibration stopped or interrupted.
E5U_
E5U_
E5U_
Advanced
None
Advisory Dual lower system calibration unsteady. System could not
determine optimum setting.
EBC_
EBC_
EBC_
Advanced
None
Advisory Run/Stop switch in Stop position (closed).
ELI_
ELI_
ELI_
Basic and
Advanced
4–5
Deviatoin Deviation hot board reset.
ERR0_
ERR0_
ERR0_
Basic and
Advanced
2–5
Deviatoin Deviation software error.
F1F0
F1F0
F1F0
None
Alarm
Fill pump flow not detected. The primary tank level has not
increased with the no flow timeout window and the no flow
timeout event is set to alarm.
F2F0
F2F0
F2F0
None
Deviation Fill pump flow not detected. The primary tank level has not
increased with the no flow timeout window and the no flow
timeout event is set to deviation.
K1D_
K1D_
K1D_
Advanced
1–2
Alarm
Flow is below minimum limit.
K2D_
K2D_
K2D_
Advanced
None
Deviation Flow is below minimum limit.
K3D_
K3D_
K3D_
Advanced
None
Deviation Flow exceeds maximum target; also indicates pump runaway
condition exists.
K4D_
K4D_
K4D_
Basic and
Advanced
1
Alarm
Flow exceeds maximum target; also indicates pump runaway
condition exists.
L1A0
L1A0
L1A0
None
Alarm
The flow rate is above the current profile flow limit set on
Profile Screen 3.
L2A0
L2A0
L2A0
None
Deviation The primary tank level is below the primary tank level low
deviation set point.
L4A0
L4A0
L4A0
None
Alarm
The primary tank level is above the primary tank level high
alarm set point.
L6CA
L6CA
L6CA
None
Deviation Port 8 is enabled and the current draw is less than 4 mA.
The BPR is requesting a value greater than 0%. Verify that
the device is connected.
L6CB
L6CB
L6CB
None
Deviation Port 9 is enabled and the current draw is less than 4 mA.
Verify that the device is connected.
MND_
MND_
MND_
Advanced
None
Advisory Maintenance counter is enabled and countdown reached
zero (0).
P1D_
P1D_
P1D_
Advanced
None
Deviation Unbalanced load. Dual Lower system — P1D1 = Motor 1 is
requiring less force to hold speed; pump lower may need
service. P1D2 = Motor 2 is requiring less force than motor
1 to hold speed.
P9D_
P9D_
P9D_
Advanced
None
Deviation Major unbalanced load — see P1D_ (P9D_ is higher
magnitude)
P1I_
P1I_
P1I_
Advanced
1–3
Alarm
Pressure is below minimum limit.