Setup
Setup
Setup Screen
Screen
Screen 16
16
16
Use this screen to monitor, set up, and control
the Intelligent Paint Kitchen peripherals. For more
information, see the Set Up Peripherals section of
the Intelligent Paint Kitchen manual 3A4030. NOTE:
The second field varies, depending on the menu
selection in the first field.
Figure 23 Setup Screen 16, Reed Switch Option
Shown
Setup
Setup
Setup Screen
Screen
Screen 16
16
16 Key
Key
Key
Select the connected peripheral from the menu.
Configures Port 4 pin 4 as an input to allow a reed switch to be connected.
The current reed switch cycle rate appears next to the cycle rate icon
in cycles
per minute.
Configures Port 4 pin 4 as an input to allow a pressure switch to be connected. If the
drum cover is lifted while this configuration is properly connected, the agitator shuts
down.
The current input status appears in the agitator status field
.
NOTE: A Supervisor Module is required for this function.
Configures Port 4 pin 4 as an output to allow for the connected device to receive an
alarm when the level of the Primary Tank is above the value that is defined in the
Primary Tank High field
.
This value is a percentage of the total level of the Primary Tank.
Configures Port 4 pin 4 as an output to allow for the connected device to receive an
alarm when the level of the Primary Tank is below the value that is defined in the
Primary Tank Low field
.
This value is a percentage of the total level of the Primary Tank
Configures Port 4 pin 4 as an output to allow for another solenoid to be connected
and controlled from the device.
Select the manual output box
and hold the button to control the auxiliary
solenoid manually. After you release the button, the manual activation is terminated.
Allows for the connected device to receive an alarm when the level of the primary tank is above
the value that is defined in this field.
Allows for the connected device to receive an alarm when the level of the primary tank is below
the value that is defined in this field.
3A2527H