Setup
Setup
Setup Screen
Screen
Screen 14
14
14
Use this screen to set your modbus preferences.
NOTE:
NOTE:
NOTE: The following are fixed modbus settings,
which cannot be set or changed by the user:
Data Bits: 8
Stop Bits: 2
Parity: None
Figure 21 Setup Screen 14
Setup
Setup
Setup Screen
Screen
Screen 14
14
14 Key
Key
Key
For systems with multiple pumps and
one display, select the pump (1 to 8)
from the menu.
NOTE: Three phase systems do not
support multiple pumps.
Select local
or remote
from
the menu. This setting applies to the
selected pump only.
Local mode allows you to view changes
over the modbus network, but you cannot
make changes over the modbus network.
Remote mode allows you to both view
and change information over the modbus
network.
Enter or change the Modbus node ID.
The value is between 1 and 246. Each
pump requires a unique node ID, which
identifies that pump if more than one
pump is connected to the display.
Select the serial port baud rate from the
menu. This is a system-wide setting.
• 38400 kbps
• 57600 kbps (default)
• 115200 kbps
Setup
Setup
Setup Screen
Screen
Screen 15
15
15
Use this screen to configure and control the tank fill
feature and Intelligent Paint Kitchen peripherals.
NOTE: The alert trigger time varies based on how far
active measurements are from their set limits.
Figure 22 Setup Screen 15
Setup
Setup
Setup Screen
Screen
Screen 15
15
15 Key
Key
Key
Select this box to manually activate the
fill solenoid output on port 4, pin 3.
NOTE: The non-editable box shows the
status of the modbus register.
Select this box to enable the tank to
automatically fill. You can then set the
fill levels.
When the tank level reaches this
level, the fill solenoid turns off.
This value cannot be higher than
the level below.
When the tank level reaches this
level, the fill solenoid turns on.
This value cannot be lower than
the level above.
Configure the low fill pump flow
notification for a deviation or an alarm
and set the time-out value in seconds.
If a 1% level change is not detected
with the timeout period in seconds, the
system takes action based on the event
type.
18
3A2527H