The Run screens display current target values and performance for a selected pump and profile. Any alarms
display in the sidebar at the right of the screen. Screens 6–9 and 10–13 display a log of the last 20 alarms for
the active pump.
The active pump and profile may be changed in Run Screens 1, 2, and 3.
Run
Run
Run Screen
Screen
Screen 1
1
1
This screen displays information for a selected
pump and profile. A box around an icon indicates
which mode the active pump and profile is running
(pressure or flow).
Figure 5 Run Screen 1
Run
Run
Run Screen
Screen
Screen 1
1
1 Key
Key
Key
For systems with multiple pumps and
one display, select the pump (1 to 8)
from the menu.
NOTE: Three phase systems do not
support multiple pumps.
Select the profile (1 to 4) from the menu.
Select the stop option
from the
menu to stop the pump.
Displays the current pump speed in
cycles per minute.
Displays the current pump pressure as a
percentage. If a transducer is used, this
icon is replaced by the pressure icon.
To set up a pressure transducer, see
Setup Screens 8 and 9, page 16
Displays current flow rate in units as
selected in
Signals the active pump to blink code 9
for identification.
Run
Run
Run Screen
Screen
Screen 2
2
2
This screen displays information for controlling an
electric agitator using the supervisor to pass on
the control set point to a Variable Frequency Drive
(VFD), also known as an inverter.
Figure 6 Run Screen 2
Run
Run
Run Screen
Screen
Screen 2
2
2 Key
Key
Key
Select this box and set the speed
setpoint for the agitator from 0–100%.
Select this box to disable network control
of the agitator and prevent the IPK touch
screen from modifying the Variable
Frequency Drive/Inverter setpoint.
Select this box and hold the softkey
button to manually control the fill pump
solenoid output.