Maintenance
32
3A6941J
7. Apply a light coating of grease to the pump rod (27)
and push it into the pump housing through the hole
in the retaining nut (9) (F
. 54).
8. Replace the two back-up rings (14) and o-ring (15)
with new back-up rings and o-ring and grease
lightly (F
9. Place the extension tube (26) over the pump rod
and tighten to pump housing (torque 32 ft-lb/43.4
N•m) (F
. 55). Apply medium strength thread
locking compound.
10. Place the ball (22) back into the pump piston (25)
11. Apply medium strength thread locking compound
on the threads of the pump rod (27).
F
IG
. 54
9
27
F
IG
. 55
F
IG
. 56
15
26
14
Pump
Housing
22
25