Maintenance
3A6941J
31
Reassemble
1. Place throat seal (32) (u-cup) into the pump
housing, lips downward (F
. 50).
2. Place the bronze washer (31) on top of the throat
seal (32) (u-cup) (F
. 50).
3. Replace the inner o-ring (30) from the retaining nut
(9) with a new o-ring and grease lightly. (F
4. Replace the outer o-ring (28) from the retaining nut
(9) with a new o-ring and grease lightly (F
. 51).
5. Place the throat screw (29) into the retaining nut (9)
using an Allen wrench and tighten (torque 16 ft-lb/
21.7 N•m)
6. Grease the o-ring (28) and place the retaining nut
(9) into the pump housing and tighten slightly (F
53).
F
IG
. 50
F
IG
. 51
32
31
30
28
F
IG
. 52
F
IG
. 53
29
9
9
28
Содержание Dyna-Star 3A6941J
Страница 11: ...Installation 3A6941J 11 Typical Wiring Single Line Parallel Systems FIG 7...
Страница 30: ...Maintenance 30 3A6941J 35 Remove the check valve and o ring 37 FIG 49 FIG 49 37...
Страница 44: ...Parts 44 3A6941J 43 42 41 58 59 52 55 56 57 54 47 48 49 50 51 53...
Страница 51: ...Mounting Dimensions Stand Alone Pump 3A6941J 51 Mounting Dimensions Stand Alone Pump...