Setup
18
3A6941J
Fill Pumps Without an Auto-fill Shut Off (AFSO)
Note: The fill pump pressure can be as high as 2000 psi, depending upon the length and diameter of Supply hose
(JJ). Graco recommends using a 36:1 ratio, or higher, air operated fill pump.
Key:
AA Remote fill station pump*
BB Remote fill station tank*
CC Filter*
DC Dust cap
G Fill port
JJ Supply hose*
H Overflow port
Y Follower plate
*User supplied
Refill the Tank: Pumps without an Auto-fill
Shut Off
F
IG
. 17
BB
AA
CC
JJ
DC
G
H
Y
Do not insert your finger into the overflow port while
filling a tank equipped with a follower plate. Injury or
amputation could result.
COMPONENT RUPTURE HAZARD
The maximum working pressure of each component
in the system may not be the same. To reduce the
risk of over pressurizing any component in the
system, know the maximum working pressure of
each component.
Never
exceed the maximum
working pressure of the lowest rated component in
the system. Over pressurizing can result in rupture,
potentially resulting in serious injury from skin
injection or splashing fluids.
Regulate pressure to the pump so that no fluid line,
component or accessory is over pressurized.