Troubleshooting
42
3A6941J
The Pump is cycling, but there is no
lubricant output from the outlet. The
Pump lost priming/pump is
cavitating.
Tank was not refilled through the fill
port. Air in the tube-in-tube was
pushed into the grease tank.
Connect the refill pump to the fill
port and fill tank to remove any air.
Airlock inside of the pump.
Remove the pump outlet check
valve and o-ring (37). Connect the
refill pump to the fill port and fill the
tank to remove air. Run the
Compact Dyna-Star until lubricant
come out. Reassemble the outlet
check valve and o-ring (37).
Grease inside of the tank is not
moving to the pump shovel tube.
Install follower plate to help
distribute grease during pump
operation.
Follower plate is not moving and is
stuck inside of the tank.
Inspect and replace follower plate, if
necessary.
Follower plate is sunk into the tank. The grease viscosity is too low.
Remove the follower plate.
The pump element parts are worn or
damaged.
Replace with new pump element
parts.
Pump is cycling, there is output of
fluid at the outlet, but pump
pressure is not building.
Pump element parts are worn or
damaged.
Replace with new pump element
parts.
Vent valve is not energized in the
single line parallel system.
Check the wiring and correct.
Vent valve is energized but not
closing (leaky vent valve).
Open the inspection plug (AB), page
12, to confirm that the vent valve is
not closing (leaky). Replace the vent
valve.
Pressure relief is leaky.
Open the inspection plug (AB), page
12, to confirm pressure relief is
leaky. Replace pressure relief valve.
Pressure in the system not reduce
and the injectors are not reset.
The vent valve is not opened to vent
pressure.
Replace the vent valve.
Problem
Cause
Solution
Содержание Dyna-Star 3A6941J
Страница 11: ...Installation 3A6941J 11 Typical Wiring Single Line Parallel Systems FIG 7...
Страница 30: ...Maintenance 30 3A6941J 35 Remove the check valve and o ring 37 FIG 49 FIG 49 37...
Страница 44: ...Parts 44 3A6941J 43 42 41 58 59 52 55 56 57 54 47 48 49 50 51 53...
Страница 51: ...Mounting Dimensions Stand Alone Pump 3A6941J 51 Mounting Dimensions Stand Alone Pump...