Troubleshooting
36
333013B
Gun does not spray
Low fluid supply.
Add fluid if necessary.
Damaged spray tip.
Replace; see
Spray Tip, and Fluid Seat Housing
Replacement
Dirty or clogged spray tip (3).
,
page 27.
Damaged fluid needle (2).
Replace, see
Piston (11) not actuating.
Check cylinder air. Check piston
o-ring (11d); see
Actuator arm (15) is out of position.
Check actuator arm and nuts. See
page 42.
Dirty air cap
Damaged or plugged air cap
,
page 27.
Air leaks from manifold
Manifold is not tight
Tighten manifold screws
Worn or missing o-rings
Replace o-rings. See page 42
Fluid doesn’t shut off properly
Fluid buildup on fluid needle (2)
Replace needle;
Piston sticking
Clean or replace o-rings. See
Excessive paint wrap back to opera-
tor
Poor grounding
Incorrect distance from gun to part
Should be 8-12 in. (200-300 mm).
Problem
Cause
Solution