Installation
12
333013B
Install the Air Line Accessories
1.
Install a bleed-type air valve (L) on the main air line
(W) to shut off all air to the gun.
2.
Install an air line filter/water separator on the main
air supply line to ensure a dry, clean air supply to
the gun. Dirt and moisture can ruin the appearance
of your finished workpiece and can cause the gun to
malfunction.
3.
Install a bleed-type air pressure regulator (M) on
each of the air supply lines (B, C, D, E) to control air
pressure to the gun.
4.
Install a solenoid valve (K) on the cylinder air line
(E) to actuate the gun. The solenoid valve must
have a quick exhaust port.
5.
Install a solenoid valve (K) to actuate the turbine.
Install the Fluid Line
Accessories
1.
Install a fluid filter and drain valve at the pump out-
let. Filtering the fluid will help remove coarse parti-
cles and sediment that could clog the spray tip.
Trapped air can cause the gun to spray unexpectedly,
which can result in serious injury, including splashing
fluid in the eyes or on the skin. The solenoid valves (K)
must have a quick exhaust port so trapped air will be
relieved between the valve and gun when the
solenoids are shut off.
The fluid drain valve is required in your system to
assist in relieving fluid pressure in the displacement
pump, hose, and gun. Triggering the gun to relieve
pressure may not be sufficient. Install a drain valve
close to the pump's fluid outlet. The drain valve
reduces the risk of serious injury, including splashing
in the eyes or on the skin.