Troubleshooting
333013B
37
Electrical Troubleshooting
Problem
Cause
Solution
Poor wrap.
Turbine air is not turned on.
Turn on.
Booth exhaust velocity is too high.
Reduce velocity to within code limits.
Atomization air pressure too high.
Decrease.
Fluid pressure too high.
Decrease, or replace worn tip.
Incorrect distance from gun to part.
Should be 8-12 in. (200-300 mm).
Poorly grounded parts.
Resistance must be 1 megohm or
less. Clean workpiece hangers.
Faulty gun resistance.
Fluid leaks from the fluid needle
packings and causes a short
Clean the fluid needle cavity and see
Faulty turbine
Faulty Power Supply
Replace power supply, see page 43
No voltage or low voltage reading on
the Pro Xp Auto Control Module
Damaged fiber optic cable or con-
nection.
Check; replace damaged parts
Turbine air is not turned on.
Turn on.
Spilled paint, dried paint, or other
contaminants inside the WB3000
Enclosure, causing a short circuit.
Clean.
Grounding cylinder not retracted
Check operation of grounding cylin-
der.
ES or Hz indicator light is not lit
(standard models only)
No power
Check power supply, turbine, turbine
ribbon cable. See
, page
43 and
ES indicator light is amber (standard
models only)
Turbine speed is too low
Increase air pressure until indicator is
green.
ES indicator light is red (standard
models only)
Turbine speed is too high
Decrease air pressure until indicator
is green
Pro Xp Auto Control Module displays
event code (smart models only)
See manual 332989 for Event Code
Troubleshooting.