The Secondary Tank Status screen displays live
operational data for the Secondary Tank installed in
the selected station.
Press
to access this screen from the Stations
screen. See
View the Stations Screen, page 102
Use this screen to view current status and to view or
change level settings for the Secondary Tank in the
selected station.
Figure 86 Secondary Tank Status Screen
Item
Item
Item
Description
Description
Description
Secondary Tank
Indicates that the information on this screen is for the Secondary Tank installed
in the selected station.
Station Number
Displays the number of the station for which information is displayed.
Press to display a keypad and select a different station to view.
Station Name
Displays the name of the currently selected station. For example, TEST1.
Actual Level
Read only. Displays the current fluid level in the Secondary Tank.
Low Level Deviation (LD)
Press to display a keypad used to set the fluid level (0–100%) at which a
Secondary Tank Low Deviation is triggered.
The Secondary Tank Low Deviation cannot be lower than the Secondary Tank
Low Alarm.
This event signals the user to refill or change the Secondary Tank before an
alarm shuts down the system.
Low Level Alarm (LL)
Press to display a keypad used to set the fluid level (0–100%) at which a
Secondary Tank Low Alarm is triggered.
The Secondary Tank Low Alarm cannot be higher than the Secondary Tank
Low Deviation.