Item
Item
Item
Description
Description
Description
Local / Remote
Control
Select Local
Local
Local to control the selected agitator and tank fill logic from the Tank Control
Module in the hazardous location.
Select Remote
Remote
Remote to control the selected agitator and tank fill logic from the Intelligent
Paint Kitchen software in the non-hazardous location.
Pressure Units
Select the units for this remote transfer pump’s pressure to be displayed in:
• psi
psi
psi
• Bar
Bar
Bar
• MPa
MPa
MPa
Agitator Speed
Units
Select the units for this Secondary Tank’s agitator speed to be displayed in:
• %
%
%
• Hz
Hz
Hz
• RPM
RPM
RPM
Flow Units
Select the units for this remote transfer pump’s flow data to be displayed in:
• Liters/min
Liters/min
Liters/min
• Gallons/min
Gallons/min
Gallons/min
• cc/min
cc/min
cc/min
• oz/min
oz/min
oz/min
• Cycles/min
Cycles/min
Cycles/min
Auxiliary Input
Function
Select the function:
• Reed
Reed
Reed Switch
Switch
Switch Count
Count
Count: Used to count the cycle rate of the fill pump.
• Agitator
Agitator
Agitator Halt
Halt
Halt: When the pressure switch attached to the tank cover elevator closes,
the pump control automatically disables the primary agitator.
Auxiliary IO
Function
Select the function:
• Reed
Reed
Reed Switch
Switch
Switch Count
Count
Count Input
Input
Input: Used to count the cycle rate of the fill pump.
• Primary
Primary
Primary Agitator
Agitator
Agitator Halt
Halt
Halt Input
Input
Input: When the pressure switch attached to the tank cover
elevator closes, the pump control automatically disables the primary agitator.
• Primary
Primary
Primary Tank
Tank
Tank High
High
High Alarm
Alarm
Alarm Output
Output
Output: Enables an alarm when the Primary Tank level is
more than the high level setting.
• Primary
Primary
Primary Tank
Tank
Tank Low
Low
Low Alarm
Alarm
Alarm Output
Output
Output: Enables an alarm when the Primary Tank level is
less than the low level setting.
• PLC
PLC
PLC General
General
General Output
Output
Output: Output control by a remote source.