Troubleshooting
Error
Code
Error
Position
Type
Name
Cause
Solution
T8DA Boost A
Bad heater rod (boost).
Measure resistance, 23 – 26
Ω, of heater rod, replace if
reading open.
T8DB Boost B
Bad hose heater.
Measure hose resistance,
replace if reading open.
T8DH Hose
ALARM
Temperature Not
Rising
Started spraying before
engine and hose reached
operating temperature.
Wait until temperatures have
been reached on engine and
hose before spraying.
V1CM MCM
ALARM
Bus Under
Voltage
Tripped circuit breaker.
Visually check circuit
breaker for a tripped
condition.
Loose or bad connection. Check wiring for loose wires.
Low generator line
voltage
Measure voltage across
main power switch (CT01).
Voltage should measure
between 190 and 264 VAC.
V1MH Hose
ALARM
Low Line Voltage
High auxiliary inrush
current.
Ensure compressor or
air drier are setup to be
continuous run and sized
according to manual.
V4CM MCM
ALARM
Bus Overvoltage
V4MH Hose
ALARM
High Line Voltage
Incoming line voltage is
too high.
Measure voltage across
main power switch (CT01).
Voltage should measure
between 190 and 264 VAC.
If voltage is too high, see
supplied alternator manual
for generator specifications
and repair.
Bad Connection between
MCM (Port 10) and brush
wear/over temperature
board.
Check connection and
cables.
WBNM MCM
ALARM
Motor Sensor
Fault
Bad brush wear/over
temperature board.
Replace Motor. See System
Repair manual.
84
3A1705E
Содержание 259079
Страница 34: ...Setup A5 A1 A2 AS AN A3 AT A3 A4 A2 A6 A4 34 3A1705E...
Страница 45: ...Advanced Display Module ADM Operation Setup Screens Navigation Diagram Figure 35 3A1705E 45...
Страница 49: ...Advanced Display Module ADM Operation Run Screens Navigation Diagram Figure 36 3A1705E 49...
Страница 93: ...Dimensions Dimensions Top View Figure 43 Side View Figure 44 3A1705E 93...
Страница 95: ...Dimensions Pallet Mounting Dimensions Figure 48 3A1705E 95...
Страница 97: ...Notes Notes 3A1705E 97...