Troubleshooting
Error
Code
Error
Location
Type
Name
Cause
Solution
CACA Boost A
Module does not have
software or dial is set to
wrong position.
Insert a system token into
the missing GCA module
and cycle the power. Wait
until the red light on the
module to stop flashing
before removing the token.
Verify the dial on the TCM's
are in the correct position:
0 for hose, A for boost A,
B for boost B
CACB Boost B
No 24v DC supply to
module.
Green light on each
module should be lit. If
green light is not lit, check
to make sure each CAN
cable connection is tight.
Verify the power supply is
outputting 24 Vdc. If not,
replace power supply. See
System Repair manual.
CAC-
H
Hose
Loose or broken CAN
cable.
Check the CAN cables
running between GCA
modules and tighten if
needed. If the problem still
persists move each cable
around the connector and
watch the flashing yellow
light on the GCA modules.
If the lights stops replace
the CAN cable.
CAC-
M
MCM
Bad module
Replace MCM. See
System Repair manual
for instructions.
CACP Remote
Display
Module
ALARM
Communication
Error
Bad module
Replace Remote Display
Module.
76
3A1705E
Содержание 259079
Страница 34: ...Setup A5 A1 A2 AS AN A3 AT A3 A4 A2 A6 A4 34 3A1705E...
Страница 45: ...Advanced Display Module ADM Operation Setup Screens Navigation Diagram Figure 35 3A1705E 45...
Страница 49: ...Advanced Display Module ADM Operation Run Screens Navigation Diagram Figure 36 3A1705E 49...
Страница 93: ...Dimensions Dimensions Top View Figure 43 Side View Figure 44 3A1705E 93...
Страница 95: ...Dimensions Pallet Mounting Dimensions Figure 48 3A1705E 95...
Страница 97: ...Notes Notes 3A1705E 97...