Troubleshooting
Error
Code
Error
Position
Type
Name
Cause
Solution
T6AE Heat
Exchanger
RTD Fault A
The module is reading
infinite resistance.
Check port on module and
wiring to RTD.
T6BE Heat
Exchanger
RTD Fault B
T6DA Boost A
RTD Fault A
T6DB Boost B
RTD Fault B
T6DE Heat
Exchanger
Coolant Outlet
RTD Fault
Bad RTD.
Switch the RTD with another
and see if the error message
follows the RTD. Replace
RTD if the error follows the
RTD. See System Repair
manual for instructions.
T6DH Hose
ALARM
RTD Cable or FTS
Fault
Broken RTD cable in
hose or bad FTS.
Expose each hose RTD
connection to check
and retighten any loose
connector. Measure
hose RTD cable and
FTS continuity. See system
repair manual. Order
RTD Test Kit 24N365 for
measurement.
See Temporary Manual
page 58, to finish job until
repair can be completed.
T8AE
Temperature Not
Rising Hx A
No coolant flow
Check coolant level. Check
for coolant flow in sight
glass.
Ensure that the circulation
pump has 240 VAC. If not,
replace the circulation pump.
See System Repair manual.
Bad valve solenoid.
Turn on the manual valve
switch (MV), on the load
center, and see if the valve
solenoid shifts. If not replace
solenoid.
T8BE
Heat
Exchanger
ALARM
Temperature Not
Rising Hx B
Bad load center.
Red, blue, and green LEDs
should light up on load
center board. If not, replace
load center.
3A1705E
83
Содержание 259079
Страница 34: ...Setup A5 A1 A2 AS AN A3 AT A3 A4 A2 A6 A4 34 3A1705E...
Страница 45: ...Advanced Display Module ADM Operation Setup Screens Navigation Diagram Figure 35 3A1705E 45...
Страница 49: ...Advanced Display Module ADM Operation Run Screens Navigation Diagram Figure 36 3A1705E 49...
Страница 93: ...Dimensions Dimensions Top View Figure 43 Side View Figure 44 3A1705E 93...
Страница 95: ...Dimensions Pallet Mounting Dimensions Figure 48 3A1705E 95...
Страница 97: ...Notes Notes 3A1705E 97...