background image

Warnings 

4

306556T

EQUIPMENT MISUSE HAZARD

 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Specifications

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. Se

Technical 

Specifications 

in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 
retailer.

Turn off all equipment and follow th

Pressure Relief Procedure 

when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 
manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Equipment can start without warning. Before checking, moving, or servicing equipment, follow the 

Pressure Relief Procedure

 and disconnect all power sources.

TOXIC FLUID OR FUMES HAZARD

 

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

WARNING

Содержание 204490

Страница 1: ...6 MPa 276 bar Maximum Working Pressure 80 psi 0 55 MPa 5 5 bar Maximum Air Pressure Model No 244637 75 1 Ratio President Pump 4000 psi 27 6 MPa 276 bar Maximum Working Pressure 80 psi 0 55 MPa 5 5 ba...

Страница 2: ...tion of Drum 12 Removal of a Drum 14 Maintenance 15 Removal of the Pump 15 Reinstallation of the Pump 15 End of Product Life 16 Troubleshooting 17 Parts 18 Ref No 25 Part No 204461 Wishbone Support As...

Страница 3: ...leaks with your hand body glove or rag Follow the Pressure Relief Procedure when you stop dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating...

Страница 4: ...ormation Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work...

Страница 5: ...er or cardboard which interrupts grounding continuity To maintain grounding continuity when flushing or relieving pressure hold metal part of the spray gun dispense valve firmly to the side of a groun...

Страница 6: ...til the pressure is fully relieved 4 If you suspect the dispense valve tip or hose is clogged or that pressure has not been fully relieved a VERY SLOWLY loosen the hose end coupling to relieve pressur...

Страница 7: ...t 2 6 m in height The elevator when fully extended is 90 in 2 4 m 2 Provide adequate space in front of the elevator for changing drums 3 Provide adequate space along the sides and back of the elevator...

Страница 8: ...rackets 83 6 Slide the support 64 down to allow installation of the pump into the inductor plate 7 Tighten the bracket screws 68 lightly Mount the Pump Models 226013 226018 244637 1 Position the pump...

Страница 9: ...screws 68 Model 25P544 Refer to FIG 5 and FIG 7 for Steps 1 6 below 1 Position the pump mounting brackets 86 then tighten the set screws to secure in place 2 Mount the bung adapter plate 117 to the pu...

Страница 10: ...elevator cap and screw it into the air inlet E in the elevator base FIG 9 2 Screw the restrictor valve assembly 42 into the elevator cap 3 Screw the 1 4 x 1 8 npt adapter 85 into the restrictor valve...

Страница 11: ...a user supplied pressure rated fluid shutoff valve not required on the fluid supply line to control the flow of fluid from the pump 11 Finish assembling the hoses and fittings as shown on Parts page...

Страница 12: ...clockwise to decrease speed counter clockwise to increase speed Tighten the jam nut once the desired speed has been set 6 Center an opened 400 lb 181 4 kg drum under the inductor plate so that the dr...

Страница 13: ...6013 226018 and 244637 only a Open the bleeder valve 94 at the pump outlet by turning the thumbscrews counter clockwise b Open the ball valve 65 until all of the air trapped in the pump and under the...

Страница 14: ...ressure is lost when reaching the drum ribs continue holding the air assist valve and slowly pull out the elevator valve until the ribs are passed Then immediately close the elevator valve to prevent...

Страница 15: ...204490 Loosen the inductor plate set screws 19 For Models 226013 226018 and 244637 Unscrew the locking nut 11 24 or 114 taking note of the number of turns needed 4 Disconnect and remove the pump from...

Страница 16: ...s useful life dismantle and recycle it in a responsible manner Perform the Pressure Relief Procedure page 6 Drain and dispose of fluids according to applicable regulations Refer to the material manufa...

Страница 17: ...blem Cause Solution Low flow or air is being sucked into pump under the inductor plate Open inductor plate vent Close the inductor plate Inductor plate sleeve locking nuts are loose Tighten the lockin...

Страница 18: ...r parts 1 91 204467 HOSE KIT See parts on page 24 1 101 205339 ELEVATOR BASE See parts on page 19 1 Ref No Part No Description Qty 21 205699 INDUCTOR PLATE ASSEMBLY See parts on page 19 1 25 204461 WI...

Страница 19: ...mbly Includes items 102 105 Ref No Part No Description Qty 102 205340 BASE elevator 1 103 100018 LOCKWASHERS spring 1 2 in 4 104 100096 SCREW hex hd cap 1 2 13 x 2 in 4 105 100321 NUT 1 2 13 4 FIG 12...

Страница 20: ...1 161107 NUT locking 1 12 161162 SEAL rubber 1 13 161287 WIPER inductor plate 1 14 161288 SEGMENT full barrel 6 15 164432 CAP vent 1 16 164497 ROD vent release 1 FIG 13 6 14 4 10 3 16 15 7 12 2 13 5 9...

Страница 21: ...88 SEGMENT full barrel 6 15 164432 CAP vent 1 16 164497 ROD vent release 1 22 205698 PLATE inductor bare 1 23 196219 RING locking 1 24 164962 NUT collet 1 FIG 15 6 14 4 10 3 16 15 7 12 22 24 23 5 9 13...

Страница 22: ...rictor Valve Assembly Includes items 43 to 46 Ref No 47 Air Assist Valve Assembly Includes items 48 to 60 43 46 44 45 1 8 npt 29 36 28 40 37 32 35 39 31 34 33 38 30 3 8 npt 52 51 60 50 49 56 59 55 48...

Страница 23: ...160404 STUD valve 1 61 204560 HOSE air cpld 3 8 npt m 3 8 in 9 6mm ID 18 in 457 mm long 1 62 204561 HOSE air cpld 3 8 npt m 3 8 in 9 6mm ID 36 in 914 mm long 2 63 205610 SUPPORT pump lower 1 64 205611...

Страница 24: ...cpld 1 4 npt m 1 4 in 6 4mm ID 6 ft 1 83 m long 1 94 205528 VALVE bleeder 1 96 160878 UNION 90 1 4 npt f swivel 1 115 156971 NIPPLE 1 4 x 1 4 npt m 1 FIG 18 115 92 1 2 npt 93 94 1 4 npt 96 Ref No Par...

Страница 25: ...Parts 306556T 25 Dimensions...

Страница 26: ...p 100 psi 0 7 MPa 7 bar Weight Model 226013 50 1 Ratio Fire Ball Pump 122 lb 55 kg Model 226018 50 1 Ratio President Pump 136 lb 61 kg Model 244637 75 1 Ratio President Pump 136 lb 61 kg Model 204490...

Страница 27: ...1 Ratio President Pump 94 6 dB A Model 244637 75 1 Ratio President Pump 94 6 dB A Maximum sound power tested at 70 psi 0 48 MPa 4 8 bar at 20 cycles per min per ISO 9414 2 Model 25P544 36 1 GT 750 Pum...

Страница 28: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...