Operation
306556T
13
9.
Push in the elevator valve (27) to lower the pump
while guiding the inductor plate into the drum.
10. Press down on the pump, rocking it back and forth,
to seat the inductor plate. This helps eliminate any
air trapped underneath the plate. Continue this
action until fluid appears at the vent opening (D).
11. Verify that the pump is aligned vertically, then
tighten the set screws (73).
12. Close the inductor plate vent by turning the knob
(10) clockwise.
13. For Models 226013, 226018, and 244637 only:
a.
Open the bleeder valve (94) at the pump outlet
by turning the thumbscrews counter-clockwise.
b.
Open the ball valve (65) until all of the air
trapped in the pump, and under the plate, is
pumped through the bleeder valve.
c.
Close the ball valve (65) and the bleeder valve
(94).
d.
Regulate the pump speed with the ball valve
(65) handle.
14. For all Models:
Always use the lowest possible
pump pressure necessary for good delivery. Higher
pressures causes premature pump wear and
usually do not produce better results.
Moving Parts Hazard
Keep fingers and hands away from the sides of the
drum and the inductor plate to avoid pinching when
raising and lowering the pump.