MMA Smart Control Operation
3A3111 A
17
MMA/Epoxy Mode
Flush Timer Setup
Flush mode is used to set the time period from when
spraying stops until the alarm notifies the operator that a
flush is required to prevent material from setting up in
the unit.
10-40 5-20 15-30 5-10
PAINT 10.0’
SPACE 30.0’
- - - JOB MIL
0.0’
MMA
BPO
2500 psi
- - - - gallons
2300 psi
0
mph
M
M/A
500
ȴ
PSI
M/A
LOW PSI
00:47
E
1
4
3
3
4
6
5
5
2
1
2
ti26782
a
Ref. Description
1
LOW PSI
is flashed if either pressure is below the
user defined MIN PSI VALUE
.
2
The progress bar will give a visual of the pressure
differential between the 2 pumps.
When the pressure differential is outside the user
defined value the progress bar will be filled and an
Error triangle will flash next to it.
3
Press the
button to RESET the Ratio Assur-
ance feature when it is enabled. The alarm will not
resume monitoring until the
MIN PSI
and the
MAX
Δ
PSI
values are again satisfied by the system.
– Enabled and monitoring
– Enabled and not monitoring
– Disabled
4
Flush Timer
indicates how much time is left on
the pot life of the mixed material in the hose. This
resets to the inputted value whenever a gun is
actuated/sprayed. Flush timer is
NOT
controlled
by pressing the
button for activation and
deactivation.
5 After material Designation is selected to input what
material or ratio is being ran, this changes the title
above each pump. MMA 98:2 shows titles: MMA
(A) and BPO. The 1:1, 2:1, 3:1 and 4:1 (epoxies)
show titles: RESIN(A) and HARDENER(B).
Ref. Description
1 When the
GUN SHUTOFF
is enabled, the guns do
not fire or shut off when the pressure drops below
the
MIN PSI VALUE
set by the user or if the pres-
sure differential is outside
MAX
Δ
PSI
value set by
the user.
2 When the
ALARM BEEP
is enabled, a beep
occurs once a second while the guns are fired if
the pressure drops below the
MIN PSI VALUE
set
by the user or if the pressure differential is outside
MAX
Δ
PSI
value set by the user.
3
FLUSH TIMER
allows the user to set a pot life
timer. This indicates to the user when the mixed
material in the hose has been sitting for the
inputted amount of time. A countdown is displayed
on the main screen and when the time reaches
zero the control will beep/flash indicating that the
user should flush the system. Flush Timer does
NOT count down if both pressures are below the
minimum setting.
4
MIN PSI VALUE
is the minimum pressure allowed
for either pump. This is defined by the user. This
can be set between 0 – 2500 psi in 100 psi incre-
ments.
5 Material Designation is selected to input what
material or ratio is being ran. This will change the
title above each pump. MMA 98:2 shows titles:
MMA (A) and BPO. The 1:1, 2:1, 3:1 and 4:1
(epoxies) show titles: RESIN(A) and HARD-
ENER(B).
6
MAX
Δ
PSI
is the maximum pressure differential
allowed for the two pumps. This is defined by the
user. Can be set between 100 – 1000 psi in 50 psi
increments. This helps ensure proper ratio.