E-Flo Plus Features
16
311596A
Table 2: E-Flo Plus Calibration Parameters / Modbus Map
Pr ID
Function
Default
Low Limit
High
Limit
Load
Defaults**
20.01
Run mode selection (0 = Programmed Cam,
1 = Constant Speed, 2 = Jog, 3 = Park).
0 (PCAM mode***)
0
3
Yes
20.02
Ramp rate selection
100gpm/min (Calibra-
tion parameter)*
10
1000
Yes
20.03
Lower Size Selection (2000cc, 1500cc,
1000cc)
2000cc (Calibration
parameter)
1000cc
2000cc
Yes
20.04
Local / Remote Control Selector
Controlled by a switch, Digital I/O #5; N.O. =
REMOTE (1)
No
20.05
Remote Mode Flow Setting (gpm x 10).
0 (Calibration parame-
ter). Multiply desired
number by 10 (12.5gpm
= 12.5 gpm x 10 = 125;
enter 125)
2000cc =
45gpm
(45);
1500cc =
32gpm
(32);
1000cc =
24gpm
(24)
2000cc =
22.6gpm
(226);
1500cc =
1.62gpm
(162);
1000cc =
12.0gpm
(120)
No
20.07
Low Pressure Alarm Setting
150 psi (Calibration
parameter)
0
2000cc =
300 psi;
1500cc =
350 psi;
1000cc =
460 psi
Yes
20.08
Low Pressure Alarm Enable
(0 = Disable, 1 = Enable)
0 - Disabled (Calibra-
tion parameter)
0
1
Yes
20.09
High Pressure Alarm Setting
300 psi (Calibration Pr)
0
2000cc =
300 psi;
1500cc =
350 psi;
1000cc =
460 psi
Yes
20.12
Motor Current x 10
0 (Calibration parame-
ter)
Multiply motor rated
current (listed on motor
identification plate) by
10 (for example, I =
6.5A => 6.5 x 10 = 65)
0
200-240V
applica-
tion = 155
380-460V
applica-
tion = 88
No
20.15
Units (0 = English, 1 = Metric)
0 (Calibration parame-
ter)
0
1
Yes
20.16
Calibration (Special parameter)
When set to 1234, it will reset system related menu 20 parameters to Graco default settings.
When set to 56, it will reset motor related parameters to Graco default settings.
When set to 777, it will allow pressure sensor calibration.