m908 User Manual, Rev. G
The meter source options are:
•
Audio Input source
This option fixes the Meter source to a specific input. The signal level is identical to the
incoming signal level.
•
Follow monitoring source selector pre level offset
This option allows the Meter source to follow whatever is being monitored on the Control
Room speakers. The signal level is identical to the incoming signal level.
•
Follow monitoring source selector post level offset
This option allows the Meter source to follow whatever is being monitored on the Control
Room speakers. The signal level follows whatever input
level offset
is set for the
currently selected input.
•
Follow DSP output.
This option sources the meter output from the final outputs for the Control Room
speakers. The meter data will have all speaker processing applied: volume, delay, offset,
Page 40 of 135
AUDIO INPUTS
DIGITAL INPUTS
ANALOG INPUTS
MONITOR
INPUT SELECT
DSP
METER OUTPUTS
METER
INPUT SELECT
AUDIO OUTPUTS
DIGITAL OUTPUTS
ANALOG OUTPUTS
LEVEL
OFFSET-
SUMMING
Illustration 26: Meter Output Routing