Grace Industries, Inc.
10
Device Settings Tab:
System ID:
(01-FE). This selection allows you to change the Grace System ID of the WorkForce®. Caution must be taken that the new ID
is not already in use and is set to be monitored.
User ID:
(01-99). This selection allows you to change the Grace User ID of the WorkForce®. Caution must be taken that the new ID is not
already in use and is set to be monitored.
Motion Timing Seconds:
This setting controls how long the user and device can remain motionless before the Man Down Alarm is
activated. A Pre-Alert warning will begin to sound approximately 12 seconds before the Man-Down Alarm, indicating the WorkForce® is
closer to going into Alarm. Available timing (in seconds) includes: 0, 30, 60, 90, 120, 180, 300, 600, and 900.
NOTE: Setting the timing to
zero (0) will DISABLE the motion sensing protection.
WARNING:
Any motion sensing alarm time period longer than 90 seconds is potentially dangerous to the user of this product. The longer
the motion sensing time period is, the greater the risk of exposing the user to a delayed response to an incapacitated, distressed worker.
CPU Firmware
Version & Build
Radio
Firmware
OEM Code
Sys ID / User ID
Device Options Tab:
Enable Alarm Audio:
With this box checked, the unit will produce the audible Alarm sound. If unchecked, no Alarm audio will be
heard and an Alarm will be indicated only by the Red Alarm Ring LEDs and Alarm Vibration.
NOTE: The audible Pre-Alert warning is not
aff ected by this setting.
Alarm Vibe Continuous:
With this box checked, WorkForce® will vibrate with every Alarm audio cycle. If unchecked, the device will
vibrate only once.
Alarm Monitor other Grace devices:
Enables Alarm Monitoring (AM) function. With this box checked, WorkForce® will alert the user
of other Grace Devices in the area that are in Alarm.
Chirp on Location Change:
With this box checked, WorkForce® will produce an audible chirp when it detects a new Grace Locator
Beacon.
Signal Loss and Out of Range Timeout (1-15 Minutes):
This function is disabled when set to zero (0). When timeout is set to 1-15
minutes, the Out of Range alert will occur if WorkForce® has not received a ping message from a base station within the set timeout
period. NOTE: To use this function, WorkForce® must be used with, and in communication with, a Grace Base (MS2000, SMS, Grace-Watch,
Alarm Box, MX900, etc.)