background image

Rev. A  92149901

7

Replace Motor Shaft Seal

•  Turn the pump off and disconnect from power.
•  Remove the gear coverplate, gears, and drive key 

as described in Gear Replacement instructions.

•  Remove the motor from the pump housing.
•  Remove the motor shaft seal by prying out with a 

small screwdriver. (Figure 13)

Back of Pump

FIGURE 13

•  Lubricate  the  gear  shaft  with  WD-40

®

 or a similar 

penetrating oil.

•  Press a new motor shaft seal evenly in the pump hous-

ing until seated. Lubricate the seal with a lightweight 

motor oil.

•  Gently slide the shaft through the seal until the motor 

is flush against the pump housing.

•  Tighten the motor to the pump housing. Check for 

proper installation by working a .0015 feeler gauge 

around the motor flange. The gauge shall not fit be-

tween the flange and the housing.

•  Install the gears and drive key as described in Gear 

Replacement instructions.

Replace Motor

NOTE:  

In order to preserve the UL Listing for pump 

safety, return the entire pump to the factory for 

motor repair or replacement. 

For products serviced 

outside the factory, the UL nameplates must be de-

faced to indicate the equipment may no longer meet 

the requirements for UL Listing. This does not apply 

to products serviced outside the factory under the 

UL program for Rebuilt Motors for Use in Hazardous 

Locations.

Содержание M-1115S

Страница 1: ...ne methanol ethanol diesel fuel up to 20 biodiesel and kerosene Please take all due pre cautions when handling these flammable liquids Your safety is important to us Also to assure the longest possibl...

Страница 2: ...4 8 feet 1 5 m with diesel 5 8 feet 1 8 m with gasoline If you require a greater initial prime height coat the gears with fluid by removing the plug on the top of the pump and pour a small quantity o...

Страница 3: ...by a licensed electrician in accordance with national state and local electrical codes regarding Class I Division 1 requirements as well as NFPA Code 70 and 30 Other codes may apply Install UL Listed...

Страница 4: ...emicals or herbicides Dispensing any fluid other than those listed in this manual will damage the pump Use of the pump with unauthorized fluids will void the warranty To Clean or Replace Strainer Turn...

Страница 5: ...thepoppetcavitythrough the top outlet port PushdownonthepoppetuntilthepoppetO ring is exposed inside the housing Figure 7 FIGURE 7 Using a clean cloth rotate the poppet and clean it thoroughly To remo...

Страница 6: ...ck wires to the switch Cut the wires close to the wire nut leaving the maximum possible length to the pump Loosen the hex nut on the switch mounting plate and remove the defective switch Strip approxi...

Страница 7: ...ntil the motor is flush against the pump housing Tighten the motor to the pump housing Check for proper installation by working a 0015 feeler gauge around the motor flange The gauge shall not fit be t...

Страница 8: ...ed Remove the bypass poppet spring and O ring Clean cavity Inspect and replace components as necessary C LOW FLOWRATE 1 Poor connections or low voltage Make sure electrical connections are secure Also...

Страница 9: ...Cover Gasket 1 13 119096 4 Switch and Circuit Breaker Assembly 1 14 110026 6 Switch Coverplate O Ring 1 15 110276 02 Switch Coverplate Assembly 1 16 110032 1 Union Ring Gasket 1 17 11030302 Cover Noz...

Страница 10: ...e defaced to indicate that the equipment may no longer meet the requirements for ULListing This does not apply to prod ucts serviced outside the factory under the UL program for Rebuilt Motors for Use...

Страница 11: ......

Страница 12: ...duct has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has been installed or operated other than...

Отзывы: