•  Install the pipe plug again.
•  Replace the gears and drive key. Make sure gears 

turn freely with the key removed.

•  Make  sure  the  gear  coverplate  O-ring  is  in  place. 

Tighten the coverplate to the pump housing.

Service Motor Wiring

•  Turn the pump off and disconnect from power.
•  Remove  the  electrical  coverplate  from  the  pump 

housing. (Figure 10) Evaluate condition of gasket. 

Replace as needed.

FIGURE 10

•  Inspect the wiring connections and cavity. (Figure 11)

FIGURE 11

NOTE: If permanent wiring is damaged or corroded, 

the pump must be returned to the factory for wire 

replacement.

•  Assemble again. Make sure the O-ring is in place 

and the coverplate is tightened securely.

Replace Switch and Circuit Breaker

•  Turn pump off and disconnect from power.
•  Remove the switch coverplate from the pump hous-

ing. (Figure 12)

FIGURE 12

•  Remove the torx head screw on the switch assembly, 

then remove the switch.

•  Clip the black wires to the switch. Cut the wires close 

to the wire nut, leaving the maximum possible length 

to the pump.

•  Loosen the hex nut on the switch mounting plate and 

remove the defective switch.

•  Strip approximately 1/4 inch (0.6 cm) insulation from 

the black pump wires and connect to the replacement 

switch wires. There are no polarity requirements.

•  Reinstall  the  new  switch  by  reversing  the  above 

procedure. Guide the switch into the housing cavity, 

pushing black wires in before the switch. Use the 

housing slot to hold the switch into place.

•  Switch mounting plate wires must clear the coverplate 

and must not be pinched. Make sure the O-Ring is 

properly seated before tightening the switch cover-

plate.

Replace Switch Lever or Switch Lever Shaft 

O-Ring

•  Turn off the pump and disconnect from power.
•  Remove the switch coverplate from the pump hous-

ing.

•  Remove the screw connecting the switch cam to the 

coverplate.

•  Remove the cam and switch lever.
•  Replace the switch lever or switch lever shaft O-Ring 

as needed.

•  Reassemble by reversing above procedure. Make 

sure the O-ring is seated properly before tightening 

the coverplate.

Содержание M-1115S

Страница 1: ...ne methanol ethanol diesel fuel up to 20 biodiesel and kerosene Please take all due pre cautions when handling these flammable liquids Your safety is important to us Also to assure the longest possibl...

Страница 2: ...4 8 feet 1 5 m with diesel 5 8 feet 1 8 m with gasoline If you require a greater initial prime height coat the gears with fluid by removing the plug on the top of the pump and pour a small quantity o...

Страница 3: ...by a licensed electrician in accordance with national state and local electrical codes regarding Class I Division 1 requirements as well as NFPA Code 70 and 30 Other codes may apply Install UL Listed...

Страница 4: ...emicals or herbicides Dispensing any fluid other than those listed in this manual will damage the pump Use of the pump with unauthorized fluids will void the warranty To Clean or Replace Strainer Turn...

Страница 5: ...thepoppetcavitythrough the top outlet port PushdownonthepoppetuntilthepoppetO ring is exposed inside the housing Figure 7 FIGURE 7 Using a clean cloth rotate the poppet and clean it thoroughly To remo...

Страница 6: ...ck wires to the switch Cut the wires close to the wire nut leaving the maximum possible length to the pump Loosen the hex nut on the switch mounting plate and remove the defective switch Strip approxi...

Страница 7: ...ntil the motor is flush against the pump housing Tighten the motor to the pump housing Check for proper installation by working a 0015 feeler gauge around the motor flange The gauge shall not fit be t...

Страница 8: ...ed Remove the bypass poppet spring and O ring Clean cavity Inspect and replace components as necessary C LOW FLOWRATE 1 Poor connections or low voltage Make sure electrical connections are secure Also...

Страница 9: ...Cover Gasket 1 13 119096 4 Switch and Circuit Breaker Assembly 1 14 110026 6 Switch Coverplate O Ring 1 15 110276 02 Switch Coverplate Assembly 1 16 110032 1 Union Ring Gasket 1 17 11030302 Cover Noz...

Страница 10: ...e defaced to indicate that the equipment may no longer meet the requirements for ULListing This does not apply to prod ucts serviced outside the factory under the UL program for Rebuilt Motors for Use...

Страница 11: ......

Страница 12: ...duct has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has been installed or operated other than...

Отзывы: