2

INSTALLATION

Installation  should  be  performed  only  by  qualified 

personnel, and in accordance with local governing 

regulations.

GENERAL  INFORMATION

This  manual  will  assist  you  in  operating  and  maintaining 

the GPI electronics supplied with your GPI meter or as an 

accessory unit on both local and remote models. The GPI 

Electronics  can  be  used  in  indoor  or  outdoor  applications 

where occasional exposure to moisture is common.

  •  The Pulse Out with Display is available in two versions. 

One indicates flowrate in units/minute and one in units/

hour. Both indicate flow totals in gallons and litres.

  •  The  Pulse Out  with  Display  can  be  used  on  all  GPI 

models, including the Precision G series, the Industrial 

Grade G2 series, the Commercial Grade A1 series, and 

the positive displacement GM Series oval gear meters.

  •  The Pulse Out with Display can be battery powered or 

externally powered.

Product  differences  in  this  manual  are  identified  by  either, 

Local 

or 

Remote

 as necessary.

The Display may come calibrated from the factory for gal-

lons “GAL” and litre “LTR” and be 

locked out

 “PRESET” to 

prevent unwanted calibrations. Field calibrations are available 

on “CAL B” and “CAL C.”
If  the  unit  was  purchased  as  an  accessory  or  remote,  the 

calibration has not been entered and the end user will be re-

quired to calibrate the display. The gallon and litre calibration 

may then be 

locked out

 using the configuration procedure.

To determine if the Pulse Out with Display has been configured 

and calibrated at the factory to your specific meter, view the 

display. If “GAL” is followed by the word “PRESET,” it has 

been configured and calibrated. If “GAL” 

is not

 followed by 

the word “PRESET,” the display must be calibrated.

  •  When measuring flammable liquids, observe precau

-

tions against fire or explosion.

  •  When  working  in  hazardous  environments,  always 

exercise appropriate safety precautions.

  •  Be sure O-rings and seals are kept in good repair. 
  •  When applying power, use DC power

 only!

  •  Disconnect external power before attaching or detach

-

ing input or output wires.

SAFETY  INSTRUCTIONS

The following installation guidelines are separated by meter 

series and mounting type.

Precision G Series:

  • 

Local 

–  The  GG510  Pulse  Out  with  Display  mounts 

directly to the 1 inch MNPT conduit connector.

  • 

Remote 

– The GG500 Pulse Out with Display connects 

via an output cable as shown in the Wiring Diagram.

Industrial Grade G2 Series:

  • 

Local 

– The GG510 Pulse Out with Display requires the 

GPI Conduit Connector Kit (Part #113437-01) for local 

mounting to the G2 series meter.

  • 

Remote 

– The GG500 Pulse Out with Display connects 

via an output cable as shown in the Wiring Diagram.

Commercial Grade A1 Series:

  • 

Local 

– The GG510 Pulse Out with Display requires the 

GPI Conduit Connector Kit (Part #113437-01) for local 

mounting to the A1 series meter.

  • 

Remote 

– The GG500 Pulse Out with Display connects 

via an output cable as shown in the Wiring Diagram.

GM Oval Gear Series:

  • 

Local 

– The Pulse Out with Display is mounted directly 

to the oval gear meter housing.

  • 

Remote 

– The GG500 Pulse Out with Display connects 

via an output cable as shown in the Wiring Diagram.

Connecting the Battery

G series and GM models are shipped with batteries. To save 

power, the display is shipped with the battery disconnected. 

To connect the battery:
1.  Remove the two large and two small screws from the 

battery coverplate located on the lower portion of the 

meter face.

2.  Insert the battery. When properly connected, numbers 

will appear in the readout.

NOTE:    To  protect  the  terminals  from  corrosion,  coat  with 

petroleum jelly.

3.  Replace the gasket and battery cover, then tighten all 

four screws.

Remote Installation

Choose a mounting location suitable for the Display. The ideal 

mounting location is where the:

  •  flowmeter is as close as possible.

  •  mounting surface has minimal vibration.

  •  ambient temperature is +14°F to 140°F (–10°C to 60°C).

  •  cable lengths are minimal.

CAUTION

Содержание GG500

Страница 1: ......

Страница 2: ...priate safety precautions Be sure O rings and seals are kept in good repair When applying power use DC power only Disconnect external power before attaching or detach ing input or output wires SAFETY...

Страница 3: ...should last up to 5 years Connection and disconnection of either power input while the other is active will not interrupt operation of the display Determine maximum power supply voltage after de term...

Страница 4: ...side of shield wire unconnected Sine Wave coil continued on next page 4 OUTPUT P U R OUTPUT P U R Connect either wire to LO F_IN terminal Connect other wire to any COM terminal Contact Closure reed s...

Страница 5: ...ground wire to any COM terminal NOTE Jumper should not connect pins marked Output P U R Open Collector Connect signal wire to HI F_IN terminal Connect ground wire to any COM terminal Connect 1K pull...

Страница 6: ...en configured and calibrated at the factory to your specific meter view the display If GAL is followed by the word PRESET it has been configured and calibrated If GAL is not followed by the word PRESE...

Страница 7: ...urves The GPI electronics have enhanced calibration features All calibration information is visible to the user as words in the upper part of the display above the numeric digits The calibration curve...

Страница 8: ...peating this entered as pulses per step Press either button briefly second NOTE If you and release it elected to enter a single K factor you must still enter a pulse rate any rate will work such as 10...

Страница 9: ...calibration mode or to begin a dispense run If you want to exit the cali bration now go to Step 11 4 If you want to continue with the calibration but have not dispens ed any fluid yet make your final...

Страница 10: ...properly Check battery connections NOT WORKING 2 Battery flat Replace battery 3 Faulty wiring connections Check wiring for loose or faulty connections 4 Faulty LCD Replace computer assembly 5 Faulty...

Страница 11: ...9 02 Adapter Kit GM005 GM007 Local 1 120509 03 Adapter Kit GM010 GM015 GM020 Local 1 5 12009601 Circuit Assembly Core 1 6 12009801 Circuit Assembly Pigtail 1 7 42100117 Jumper 2 Circuit 1 8 901002 82...

Страница 12: ...13 Screw 6 32 x 1 2 in Remote Model 4 10 904002 44 Screw 8 32 x 5 16 in 2 11 125066 20 Cable 20 ft 1 125066 3 Cable 100 ft 1 Item No No Part No Description Req d 12 902005 9 Strain Relief 1 13 901002...

Страница 13: ...M020 Shipping Weight 1 lb 45 kg SPECIFICATIONS REMOTE MODEL Materials Acetal Amorphous Nylon PET Polyester Polyester de cals Viton gasket seals Stainless Steel fasteners PVC cable jacket Power Source...

Страница 14: ...14 DIMENSIONAL DRAWINGS...

Страница 15: ...ease contact GPI before returning any part It may be possible to diagnose the trouble and find a solution with a telephone call GPI can also inform you of any special require ments you will need to fo...

Страница 16: ......

Отзывы: