Description and Specifications

This Self-Priming – Centrifugal Pump is designed to 

pump muddy water with minute quantities of suspended 

solids. When pumping water, the pumps are self priming 

on static suction lifts up to 25 feet (7.6 meters), while 

with liquids which foam or foam emulsions, the static 

suction lift is reduced to 10 feet (3 meters). A cast iron 

impeller with solids handling capabilities is used.

THIS PUMP IS DESIGNED TO PUMP 

WATER. NEVER USE THIS SELF 

PRIMING PUMP TO PUMP FUEL, 

FLAMMABLE, CORROSIVE OR 

COMBUSTIBLE LIQUIDS. PUMPING 

ABRASIVE LIQUIDS IS ALSO HAZ-

ARDOUS. IF IN DOUBT, CONSULT 

FACTORY FOR PROPER USE AND 

APPLICATION.

1. Important Safety Precautions

BEFORE USING YOUR SELF-PRIM-

ING – CENTRIFUGAL PUMP, READ 

AND FOLLOW THESE SAFETY PRE-

CAUTIONS.

  1. Never use these pumps for pumping flammable liq-

uids such as diesel or gasoline.

  2. Before starting the pumps, follow all of the instruc-

tions in this manual and any supplemental instruc-

tions supplied with the pump.

  3. Any person operating this pump and its power unit 

should be fully aware of its safe operation before they 

start using it.

  4. Never operate an engine driven unit in an explosive 

atmosphere, near combustible materials, or where 

insufficient ventilation exists unless specific provi-

sions have been made regarding the power unit so 

as to prevent possible injury and damage. Be certain 

the power unit is safe for the area in which it is to be 

operated.

  5. Always be sure the unit is on a secure footing. Keep 

the immediate pump area free of all unauthorized 

personnel. If the pump is sitting beside a pit, be sure 

it is well anchored so that it does not fall in.

  6. Never operate the unit with any guards removed.
  7. Do not overtighten the drain or filler plugs.Excessive 

force may damage the threads or the pump body.

  8. With engine driven pumps: A) Observe all safety pre-

cautions for the handling of fuel. B) Never refuel the 

engine while running. C) Never refuel a hot engine. 

D) Run engine only in well ventilated areas.

  9. Before working on this pump make sure the power 

unit cannot inadvertently be started.

10. Be sure the power unit, pump, wiring and piping 

installations are suitable for the liquid being pumped 

and comply with all applicable codes and regulations.

11. Use at least 12" (300 mm) of flexible hose to make 

plumbing connections to the pump body. Rigid pip-

ing may put stresses on the pump, causing damage. If 

rigid piping must be used, properly support it so as to 

eliminate stresses on the pump.

12. Do not run the pump dry. Always fill the pump body 

with water before starting. It is not necessary to drain 

the pump body after use, unless there is danger of 

freezing, settling of solids, or crystallization.

13. Do not subject pump to extreme conditions of acidity 

or basicity. Consult factory for specific recommenda-

tions concerning chemicals and temperatures.

14. Only use original spare parts.

2. Before Starting

2.1 A suction strainer should be attached to the suction 

hose or pipe. It is provided with holes or slots small 

enough to prevent big stones, etc., from working 

through and damaging the pump. Keep the strainer 

clean. If possible, suspend the strainer to keep it from 

working into the sediment. Or, 

 

 

A) Prepare a bed of stones on which to rest the strainer. 

B) Tie the strainer inside a basket or pail.

2.2 Fill the engine crankcase and air cleaner with oil as 

specified in the Engine Manual.

2.3 FUEL: Regular gasoline (leaded or unleaded) which 

can be mixed to the extent of 10% by volume with 

ethanol. DO NOT use methanol.

2.4 Fill the pump with water through the priming port 

on the top of the pump. Remember the pump is self-

priming only when the pump is filled.

2.5 Make certain that all hose and pipe connections are 

airtight.

IMPORTANT: An air leak in the suction line may  

prevent priming and will reduce the 

capacity of the pump. Use sealant on all 

threaded connections.

WARNING

CAUTION

Table of Contents

SUBJECT  

PAGE

Important Safety Precautions ......................................... 2
Before Starting .............................................................. 2
Operating Instructions ................................................... 3
Repair Parts ................................................................... 3
Troubleshooting ............................................................ 4
Goulds Water Technology Limited Warranty ................. 4

Owner’s Information

Please fill in data from your pump nameplate. 

 

Warranty information is on page 4.
Pump Model:   

         

Serial Number:
Dealer:
Dealer’s Phone Number:
Date of Purchase:
Installation Date:

Содержание 2AUW

Страница 1: ...2AUW 2AUW 3AUW INSTALLATION OPERATION AND TROUBLESHOOTING INSTRUCTIONS INSTRUCTION MANUAL IM085 3AUW ...

Страница 2: ...p make sure the power unit cannot inadvertently be started 10 Be sure the power unit pump wiring and piping installations are suitable for the liquid being pumped and comply with all applicable codes and regulations 11 Use at least 12 300 mm of flexible hose to make plumbing connections to the pump body Rigid pip ing may put stresses on the pump causing damage If rigid piping must be used properly...

Страница 3: ...res less than 2 minutes To further reduce priming time the engine speed may be increased after the engine is properly broken in If pumping does not start within this time shut off engine and check to find the difficulty see Trouble shooting 3 3 CONTROL On high suction lifts a higher engine speed is necessary On shallow lifts or when there is but a little liquid to pump save fuel and engine life by...

Страница 4: ...ther legal relationship which engages in the business of selling or leasing pumps to customers 3 Customer means any entity who buys or leases the subject pumps from a dealer The customer may mean an individual partnership corporation limited liability company association or other legal entity which may engage in any type of business THIS WARRANTY EXTENDS TO THE DEALER ONLY 4 Troubleshooting A PUMP...

Страница 5: ...2AUW AUW Bomba de autocebado con motor de impulsión MANUAL DE INSTALACIÓN OPERACIÓN E IDENTIFICACIÓN Y RESOLUCIÓN DE PROBLEMAS MANUAL DE INSTRUCCIÓN IM085 3AUW ...

Страница 6: ... mientras está funcionando C Nunca abastezca combustible a un motor caliente D Haga funcionar el motor en áreas bien ventiladas únicamente 9 Antes de trabajar en esta bomba asegúrese de que la unidad de energía no pueda arrancarse accidental mente 10 Asegúrese de que la unidad de energía la bomba el cableado y las instalaciones de tuberías sean adecua das para el líquido que se está bombeando y qu...

Страница 7: ...stá más de 30 metros 9 metros en direc ción vertical se recomienda instalar una válvula de retención en dicha línea cerca de la bomba para evitar el destructivo ariete de agua cuando la bomba está apagada En este caso podría ser necesario ventear el extremo superior de la bomba para que pueda ex pulsarse el aire durante el recebado automático Esta purga de aire puede lograrse proporcionando una lí...

Страница 8: ...ad limitada asociación o cualquier otra persona jurídica con actividades en cualquier tipo de negocios LA PRESENTE GARANTÍA SE EXTIENDE AL COMERCIANTE ÚNICAMENTE 3 5 Si la manguera flexible debe tenderse atravesando un camino protéjala con tablones La presión de cierre instantánea aplicada cuando un vehículo pasa sobre una manguera sin protección producirá un choque hidráu lico cuál puede dañar la...

Страница 9: ...MANUEL D UTILISATION IM085 2AUW AUW Pompe auto amorçante à moteur à combustion MANUEL D INSTALLATION D UTILISATION ET DE DÉPANNAGE 3AUW ...

Страница 10: ...pendant que le moteur est en marche c ne jamais faire le plein quand le moteur est chaud d faire fonctionner le moteur uniquement dans un endroit bien ventilé 9 Avant d effectuer tout travail sur la pompe s assurer que le moteur ne peut être mis en marche par inadvertance 10 S assurer que le moteur la pompe le câblage et la tuyauterie sont appropriés au liquide pompé et conformes aux codes et règl...

Страница 11: ...sque le corps de pompe est rempli d eau 5 S assurer que tous les raccords de tuyauterie sont étanches IMPORTANT toute fuite dans la tuyauterie d aspiration peut empêcher l amorçage et réduire le débit de la pompe Employer un produit d étanchéité pour tous les raccords filetés 6 Placer la pompe sur une surface portante solide et de niveau aussi près que possible du liquide à pomper mais pas plus ha...

Страница 12: ...ener l air purgé directement dans la source de liquide Nous ne serons nullement tenus responsables des dommages causés à la pompe par l absence d un clapet de non retour sur le tuyau de refoulement Si la lubrification et le plein sont effectués correctement la pompe fonctionnera sans surveillance 5 Lorsqu un tuyau souple doit traverser une voie carrossable le protéger en le bordant de madriers pou...

Отзывы: