Nameplate field
Explanation
FLOW
Rated pump flow, in gallons per minute
HEAD
Rated pump head, in feet
RPM
Rated pump speed, in revolutions per minute
HYDRO PRESS
Hydrostatic pressure at 100°F, in pounds per square inch
MAX. DES. WORKING PRESS
Maximum working pressure at temperature °F, in pounds per square inch
S/N
Serial number of the pump
CONT./ITEM NO.
Customer contract or item number
IMP. DIA.
Rated impeller diameter
MAX. DIA.
Maximum impeller diameter
STD. DIM.
Standard ANSI dimensional code
MAT'L
Material of construction
ATEX nameplate
Figure 8: ATEX nameplate
Nameplate field
Explanation
II
Group 2
2
Category 2
G/D
Pump can be used when gas and dust are present
T4
Temperature class
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure that the code classifications on the pump are compatible with the specific environment
in which the equipment is to be installed. If they are not compatible, do not operate the