Transportation and Storage
Model 3410 Installation, Operation, and Maintenance Manual
14
Figure 2: The proper lifting method for a horizontal pump on a base with lifting holes
Figure 3: The proper lifting method for a horizontal pump on a base without lifting holes
Pumps mounted vertically
Pump mounting
Lifting method
Half pedestal
Place a nylon sling chain or wire rope around both flanges. Use a latch
hook or standard shackle and end loops. Be sure the lifting equipment
is long enough to keep the lift angle less than 30° from the vertical.
Full pedestal
Install eyebolts in the three holes provided at the top of the support
and tighten securely. Attach a chain or wire rope using a latch hook or
standard shackle and end loop. You must use shoulder eyebolts that
are manufactured per ANSI B18.15 and sized to fit the holes provided.
Be sure the lifting equipment is long enough to keep the lift angle less
than 30° from the vertical.
1. Nylon sling, chain, or wire rope
Figure 4: The proper lifting method for a vertical pump mounted on a half pedestal