Device Description HG G-19370ZA | English, Revision 01 | Date: 17.05.2017 | www.goetting-agv.com
25
Chapter 9: Technical Data
9
Technical Data
Technical data inductive guidance sensor
Casing
156,5 x 53 x 21 mm (W x H x D)
Height including connectors: 66 mm
Polycarbonat (PC)
Weight
approx. 200 g
Protection Class
IP 54
Relative humidity at 25° C
95% (without condensation)
Operating temperature range
-20° C to +50° C
Storage temperature range
-20° C to +70° C
Supply voltage
5 V (USB)
Nominal (vehicle): 12V – 24 V
Maximum: 10 V – 30 V
Current consumption
60 mA @ 24 V
Reading height
60 – 200 mm
Nominal reading height 60 mm (preset)
Higher reading distances via programmable
gain
Frequencies
6 programmable Frequencies, simultaneously
usable, 2 – 20 kHz, 100 Hz resolution
Measuring rate
100 Hz (every 10 ms a new value is calculated)
Connectors
3 M12 circular connectors A coded:
ST 1
8 pin male, USB, incremental encoder
CAN 1 / CAN 2
5 pin female/male, CAN bus
USB
Configuration / firmware update
with emulation of a serial interface
Incremental encoder
Input for the processing of an incremental
encoder. All incremental encoders can be used
that have a switching threshold > 10 V
between high level and low level (typically 24V
incremental encoders).
Output via CAN.<
Table 9
Technical Data