Edit 1 – Modulator 2 T2 rise time:
Value: 0 to 255. The time it takes to rise to full value.
This
value is only completely active, if the morph control on Modulator 2 edit page 7 are in
position zero, and morph modulation has the value + 0.
Edit 1 – Modulator 2 T3 hold time1:
Value: 0 to 255. The time it will hold at full value.
This
value is only completely active, if the morph control on Modulator 2 edit page 7 are in
position zero, and morph modulation has the value + 0.
Edit 1 – Modulator 2 T4 fall time:
Value: 0 to 255. The time it takes to fall from full value to
zero.
This value is only completely active, if the morph control on Modulator 2 edit page 7 are
in position zero, and morph modulation has the value + 0.
Edit 1 – Modulator 2 T5 hold time2:
Value: 0 to 255. The time it will hold at value zero.
This
value is only completely active, if the morph control on Modulator 2 edit page 7 are in
position zero, and morph modulation has the value + 0.
Edit 1 – Modulator 2 T1 b delay time:
Value: 0 to 255. The time from it is resat, until the rise
time starts.
This value is only completely active, if the morph control on Modulator 2 edit page
7 are in position 255.
2 T2 . T3 . .
X 0 0 .
3 T4 . T5 . .
X 0 0 .
4 T1b . . .
X 0 .