![Gossen MetraWatt METRALINE PAT Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/gossen-metrawatt/metraline-pat/metraline-pat_operating-instructions-manual_2247297002.webp)
2
GMC-I Messtechnik GmbH
Table of Contents
Page
Page
Safety Precautions .....................................3
General ................................................................3
Meanings of Symbols on the Device .......................4
Meanings of Symbols in the
Operating Instructions ...........................................4
Applications ...............................................5
Standard Equipment and Accessories .......5
Scope of Delivery ..................................................5
Accessories ..........................................................5
Connection, Control and Display Elements 6
Functions Description ................................7
Power Supply .......................................................7
Measurement Data Processing ..............................7
USB Port ..............................................................7
Bluetooth Interface ................................................8
Checking the Mains Connection ................8
Connection Display ...............................................9
Single-Phase Mains Connection .............................9
Display and Menu Structure ......................9
Initial Startup of the Test
Instrument .................................................9
Visual Inspection ...................................................9
Mains Connection .................................................9
Selecting and Starting a Test .................................9
Data Transmission ...................................10
Transmitting Measured Values to the PC ..............10
Single Measurements ..............................10
/ RPE – Protective Conductor Resistance .......11
Connection Type Selection ..............................11
RPE – Permanently Connected DUTs ...............13
RPE – Probe-Probe Measurement ...................14
RPE – Balancing the Probe Cable for the
Protective Conductor Measurement .................15
– Insulation Resistance ................................16
RISO – LN-PE ................................................17
RISO – LN-Probe ............................................18
RISO – Probe-PE ............................................19
RISO – Probe-Probe (GND) ..............................20
RISO – L-N ....................................................21
– Equivalent Leakage Current Measurement ....22
– LN-PE ....................................................23
– LN-Probe ...............................................24
– Probe-Probe (GND) ................................. 25
10.4 AKTIV - Function Test and Leakage Current
Measurements ................................................... 26
10.5 U – Testing the DUT (ELV) in the Presence of Line
Voltage .............................................................. 27
Error Messages, Troubleshooting ........... 28
Measurement ..................................................... 28
11.5 Bluetooth Communication ................................... 28
Technical Data ........................................ 29
Maintenance ........................................... 31